elektraLite Elektric Eye User Manual Download Page 14

13

 - 

3. Press

 [ENTER]

 or 

[EXIT/DN]

 to exit. 

 

- Lamp running time 

This function displays the running time of the lamp.

 

1. Select 

“LATI”

 by pressing 

[UP]

 button. 

2. Press

 [ENTER]

, the display shows 

“XXXX”

, “X“ stands for the number of hours. 

3. Press

 [ENTER]

 or 

[EXIT/DN]

 to exit. 

 

- Clear fixture time 

This function clears the running time of the device.

 

1. Select 

“CLMT”

 by pressing 

[UP]

 button. 

2. Press

 [ENTER]

, the display shows 

“ON”

 or 

“OFF”

3. Press 

[UP]

 to select 

“ON”

 to enable this function or 

“OFF”

 if you don’t. 

4. Press 

[ENTER]

 to confirm. 

5. Press 

[EXIT/DN]

 to return to the main menu. 

 

- Clear lamp time

 

This function clears the running time of the lamp.   
Please clear the lamp time every time you replace the lamp.

 

1. Select 

“CLLT”

 by pressing 

[UP]

 button. 

2. Press

 [ENTER]

, the display shows 

“ON”

 or 

“OFF”

3. Press 

[UP]

 to select 

“ON”

 to enable this function or 

“OFF”

 if you don’t. 

4. Press 

[ENTER]

 to confirm. 

5. Press 

[EXIT/DN]

 to return to the main menu. 

 

- Main menu 5 

 
 
1. Press 

[ENTER]

 for 3 seconds to enter the main menu 

(display flashing). 

2. Press 

[UP]

 to select 

“EDIT”

 

- Define the number of steps in Run 

This function defines the number of steps in the Program 
Run. 
1. Select 

“STEP”

 by pressing 

[UP]

 button. 

2. Press

 [ENTER]

, the display shows 

“S-XX”

, “X” stands   

for the total amount of steps you want to save, so you   
can call up to 48 scenes in 

“RUN”

.  

For example if the “XX” is 05, it means that 

“RUN”

   

will run the first 5 scenes you saved in 

“EDIT”

3. Press 

[ENTER]

 to save and exit. 

 

- Editing the channels of the individual scenes 

This function edits the program to be called up in Run. 
 

a) Editing via the Control Board 

1. Select 

“SC01”

 by pressing 

[UP]

 button. 

2. Press 

[ENTER]

, the display shows 

“SCXX”

, “X” stands   

for the scene no. to be edited. 

3.  Change the scene no. by pressing 

[UP]

4. Press 

[ENTER]

, the display shows

 “C-X”

, “X” stands   

Summary of Contents for Elektric Eye

Page 1: ...THE ELEKTRIC EYE USER MANUAL V1 02 Elektralite is a division of Group One 70 Sea Lane Farmingdale NY 11735 USA Tel 1 516 249 3662 Fax 1 516 249 8870 WWW MYELEKTRALITE COM...

Page 2: ...ite CP10xt or CP20xt You can save a maximum of 48 scenes You can then run this saved program by using the run feature from the menu on the display panel SAFETY INSTRUCTIONS A Word of Caution Please re...

Page 3: ...ubs theatres and so on This fixture should only be operated at the voltage which is stated in the technical specifications in the last page of this manual The Elektric Eye is designed for indoor use o...

Page 4: ...lamp is not acceptable Procedure 1 Unscrew the 2 screws on the back of the housing that hold the lamp housing plate in position 2 Gently pull the plate out using the knob in the middle of the plate 3...

Page 5: ...G Clamp can be used instead of a half Cheeseboro Or even a piece of thread rod can be fitted to the Omega clamp 3 Safety chain Fit the half cheeseboros or C clamps to the U brackets Then fit the U br...

Page 6: ...a tendency for electrical noise to be evident In which case a DMX terminator will be required The terminator helps prevent corruption of the DMX signal To make a DMX terminator simply solder a 120 ohm...

Page 7: ...ave its first channel or starter address at channel 9 The third Elektric Eye will then have its first channel or starter address at channel 17 and so on Now if you want two Elektric Eyes to be always...

Page 8: ...ons ALON AU A Automatic Program Run in Stand Alone AUTO MAST AU M Automatic Program Run as Master ALON SO A Sound controlled Program Run in Stand Alone RUN SOUN MAST SO M Sound controlled Program Run...

Page 9: ...urn to main menu Slave setting This function defines Elektric Eye as slave 1 Select SLAV by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable t...

Page 10: ...channel If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENT...

Page 11: ...er This function switches the lamp on or off via an external controller 1 Select ONLI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON to enable this function or...

Page 12: ...it resolution 1 Select 16BI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON to set 16 bit or OFF to set 8 bit The channels PAN Fine and TILT Fine will be disabl...

Page 13: ...ess ENTER the display shows ON or OFF 3 Press UP to select ON to enable this function or OFF if you don t 4 Press ENTER to confirm 5 Press EXIT DN to return to the main menu Test function of each chan...

Page 14: ...o select ON to enable this function or OFF if you don t 4 Press ENTER to confirm 5 Press EXIT DN to return to the main menu Main menu 5 1 Press ENTER for 3 seconds to enter the main menu display flash...

Page 15: ...conds to run the current scene 12 Adjust the desired time by pressing UP 13 Press ENTER to save the settings for the scene you are editing the display will change to the next scene automatically 14 Re...

Page 16: ...ect one of the 6 gobo s open or gobo cycle gobo shake CHANNEL 3 select gobo rotation speed and direction CHANNEL 4 Strobe 0 10Hz CHANNEL 5 pan movement max 630 CHANNEL 6 tilt movement max 265 CHANNEL...

Page 17: ...cont rotation 0 9 Open 10 19 Rot gobo 1 20 29 Rot gobo 2 30 39 Rot gobo 3 40 49 Rot gobo 4 50 59 Rot gobo 5 60 69 Rot gobo 6 70 89 Gobo 1 shake slow to fast 90 109 Gobo 2 shake slow to fast 110 129 Go...

Page 18: ...t Channel 7 Speed pan tilt movement 0 4 max speed 5 225 max to min speed 226 235 blackout by movement 236 245 blackout by all wheel changing 246 255 no function Channel 8 Lamp on off reset internal pr...

Page 19: ...will appear after resetting Elektric Eye and the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor is defective or it could be the drive circuit on the main...

Page 20: ...amp is off disconnected from the 120 supply and when it is cool TECHNICAL SPECIFICATIONS Power supply 120VAC 60Hz Power consumption max 400 VA Lamp MSD250 2 GY9 5 socket Metal Halide Motors 8 micro mo...

Page 21: ...Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Page 22: ...CP 20xt Controller TurboFog Fog Machine...