Select the required security level by using the
UP&DOWN
buttons – Then press
SEL,
4.
The display will change to show the current sensitivity
setting for that security e.g.
Level 5 050
5.
To change the sensitivity setting use the
UP&DOWN
buttons until the desired setting is reached – Then press
SEL,
6.
The new sensitivity level will be stored and the display will return to show the current
security level number as above.
NOTE: The sensitivity setting on security level NC is fixed according to NILECJ – Level 2
and cannot be altered.
The above procedure can be repeated for each security level, by repeating points 2 – 5 as above
for any security level requiring to be designated.
When sensitivity adjustments are complete, other programming options may be accessed by
pressing the
UP&DOWN
buttons to select the required
sub
-MENU or press
RUN(X)
to return to
the normal operating mode.
4.1.2 SECURITY ZONE AND SENSITIVITY LEVEL ADJUSTMENTS
(
*for
ThruScan
sX/ sX-WP /s15-i/sX-i
)
The detection areas for
ThruScan
sX/ sX-WP
are divided into 3
sections; bottom zone (ZONE 1), middle zone (ZONE 2) and top zone
(ZONE 3). Exclusively the sensitivity level of
ThruScan
can be
adjusted separately in each zone. i.e. / the middle zone of
ThruScan
may be adjusted to be more or less sensitive in comparison to the top
or the bottom zones.
The detection areas for
ThruScan
sX-i
are divided into 9 separate zones from top to bottom and
the sensitivity level of each zone can be adjusted separately
regardless of each other.
By this feature, the sensitivity level of zone 2 in which there would
more likely be keys, cellular phones, belts etc. can be decreased while
the other zones’ can be increased.
NOTE: The general sensitivity level adjustments are dominant (pls. see section 4.1.1).
Therefore any separate sensitivity level adjustment of the zones will not be valid after
such preliminary setting.
4.1.3 AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGNMENT
(
* only for
ThruScan
sX/ sX-WP /s15-i/sX-i)
This feature is rare worldwide and its MENU helps the user to decide and to assign the required
sensitivity level rapidly.
ZONE
ZONE 2
20
ZONE 3
30
ZONE 4
40
ZONE 5
50
ZONE 6
60
ZONE 1
10
NEW VALUE
050
SECURITY LEVEL
LEVEL 5
050