Elektra Beckum Compresor Power 260 Operating Instructions Manual Download Page 6

10

ENGLISH

After all servicing:

Check to see that all safety
devices are operational.

Make sure that no tools or other
parts remain on or in the device.

Compressor does not run:

No mains voltage. 

Check cables, plug, outlet and
mains fuse. 

Mains voltage too low. 

Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
device. 

Compressor was stopped by
unplugging. 

Switch compressor OFF at the
On/Off switch, then ON again. 

Motor has overheated, caused by
insufficient cooling (cooling fins
covered). 

Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again. 

Compressor runs but does not build 
up sufficient pressure.

Condensate drain of pressure ves-
sel leaky.

Check gasket of drain screw(s);
replace if necessary. 

Tighten drain screw(s) fingertight. 

Check valve leaky.

Have check valve serviced by
qualified service centre. 

Air tool is not supplied with sufficient 
pressure.

Pressure regulator not opened wide
enough.

Open pressure regulator more. 

Hose connection between compres-
sor and air tool leaky.

Check air hoses, replace defec-
tive parts if necessary. 

A

Danger!
Repairs to power tools must be

carried out by qualified electricians
only!

Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address. 

Please attach a description of the fault to
the power tool. 

The device's packaging can be 100 %
recycled. 

Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled. 

These instructions are printed on chlo-
rine-free bleached paper. 

7.

Repairs

8.

Environmental Protection

9.

Technical Specifications

Suction capacity 

l/min

235 

Free air delivery (volume flow rate) 

l/min

110 

Filling rate 

l/min

120 

Max. working pressure 

bar

Pressure vessel volume 

l

Pump model 

F 245 

No. of cylinders 

Motor speed 

min

-1

 2850 

Motor capacity 

kW

1.5 

Supply voltage (50 Hz) 

V

230 

Rated current 

A

6.8 

Fuse protection min.

A

10 (time-lag) 

Degree of protection 

IP 20 

Maximum overall length when using extension cables with: 
– 3 x 1.0 mm

2

 lead cross-section 

– 3 x 1.5 mm

2

 lead cross-section 

– 3 x 2.5 mm

2

 lead cross-section 

m
m
m

10 
25 
25 

Dimensions: length x width x height 

mm

600 x 310 x 405 

Weight kg

18 

Sound pressure level at 1 m max.

dB (A)

87 ± 3 

Reviews: