The parameters can also be changed with a text editor software. The following example of a ”BATPARS .xml” file
shows the
default values
:
I
<BatPars>
<SETUP_DISABLED>
0
</SETUP_DISABLED>
* Setup - Menu – Locking (1=locked menu)
<TIMEZONE>
2
</TIMEZONE>
Time zone GMT + 2h
<BACKLIGHT_MODE>
1
</BACKLIGHT_MODE>
Mode of display backlight operation
<GPS_MODE>
1
</GPS_MODE>
PS 0=off, 1=on, 2=on with GPX recording
<GPS_FORMAT>
1
</GPS_FORMAT>
PS - coordinates – display format
<GPS_INTERVAL>
10
</GPS_INTERVAL>
Refresh positon every X s
<PLAYBACK_SPEED>
10
</PLAYBACK_SPEED>
Frequency divider rate (playback speed)
<PLAYBACK_VOL>
5
</PLAYBACK_VOL>
Loudness at the headphone jack/speaker
A
<PLAYBACK_MODE>
1
</PLAYBACK_MODE>
Playback mode 0=Pitch,1=Mixer
<MONITORING>
1
</MONITORING>
Live monitoring
A
0=off, 1=on
<PRETRIG_TIME_MS>
500
</PRETRIG_TIME_MS>
* Recording time before the first trigger in ms
<POSTTRIG_TIME_MS>
1000
</POSTTRIG_TIME_MS>
* Recording time after the last trigger in ms
<AUTOTRIG_MAXTIME_MS>
53500
</AUTOTRIG_MAXTIME_MS>
* Max. recording time per automatic trigger in ms
<MANTRIG_MAXTIME_MS>
10000
</MANTRIG_MAXTIME_MS>
* Max. recording time per manual trigger in ms
<TRIG_MODE>
2
</TRIG_MODE>
Trigger mode (Man./Cont./CrestAdv/Crest/Period)
<TRIG_AUTOREC>
1
</TRIG_AUTOREC>
Autostart recording on trigger event
<TRIG_NRBLOCKS>
2
</TRIG_NRBLOCKS>
* Nr. of FFT blocks for check of valid trigger event.
<TRIG_PAR0>
6
</TRIG_PAR0>
Crest: min. Crest factor for triggering
<TRIG_PAR1>
2
</TRIG_PAR1>
Crest: min. RMS value for triggering
<TRIG_PAR2>
2
</TRIG_PAR2>
Crest: min. peak value for triggering
<TRIG_PAR3>
6
</TRIG_PAR3>
Crest: min. frequency for triggering (x 1,22 kHz)
<TRIG_PAR4>
8
</TRIG_PAR4>
Period: MN*SD of periods in test interval (ProdVal)
<TRIG_PAR5>
20
</TRIG_PAR5>
Period: SD/MN of periods (*100) in test int. (DivVal)
<TRIG_PAR6>
7
</TRIG_PAR6>
Crest Adv: min. Crest factor for triggering
<TRIG_PAR7>
15
</TRIG_PAR7>
Crest Adv: min. frequency for triggering in kHz
<TRIG_PAR8>
155
</TRIG_PAR8>
Crest Adv: max. frequency for triggering in kHz
<RECDLY_NRDAYS>
0
</RECDLY_NRDAYS>
Nr. of days for time windowed recordings
<RECDLY_T1START>
00:00
</RECDLY_T1START>
Start time 1, start of 1
st
time window
<RECDLY_T1STOP>
00:00
</RECDLY_T1STOP>
Stop time 1, end of 1
st
time window
<RECDLY_T2START>
00:00
</RECDLY_T2START>
Start time 2, start of 2
nd
time window
<RECDLY_T2STOP>
00:00
</RECDLY_T2STOP>
Stop time 2, end of 2
nd
time window
<RECINTVL_MIN>
0
</RECINTVL_MIN>
Recording interval in minutes
</BatPars>
*
identifies parameters, that can only be set
by changing the values in the file ”BatPars.xml”.
They are not “visible” or accessible through the
setup menu of the BATLOGGER!
BATLOGGER Manual
Elekon AG Nov. 2012
23/28