eLEDing eSenlite SMART EE112W Series User Manual Download Page 2

User Tips and Warning!

Keep it away from the children during the installation.
Avoid installing where the temperature or humidity is high.
Avoid placing objects in front of the motion detector that may affect illuminating performance.
Avoid installing the unit near air conditioners, central heaters, or outdoor area without water/weatherproof 
protection. 
As  with  a  typical  DIY  or  replacement  light  project  for  custom-made  considerations  visit  your  local  hardware 
store  or  consult  experienced  electric  technician  for  assistance  on  your  specific  mounting  accessories  and 
installation needs. User and Installer have to consider application site’s environmental condition and specific 
lighting purpose to decide best mounting and installation arrangement.
 All installation procedures must follow their local safety standards and building, electric regulations. 

Specifications

Important Safety Information

Do not dispose of this plastic unit in fire. This may result in an explosion.
Do not expose the light to fire or intense heat as the battery may explode.
Do not immerse in water.
Never look directly into the light or shine it into another person’s eyes.
Follow proper safety tips to prevent from falling off a ladder.
Consult your local construction/bulding safety guide if needed for installing 
the light fixture on a building.

One Year Limited Warranty

 guarantees this product to be free from defects in material & workmanship for (1) year. 

This warranty does not apply to damage from misuse or incorrect installation/ connection. 
This warranty does not cover accessories, bulbs, batteries, high voltage accidents, alterations, unauthorized use or repair, neglect, misuse, abuse, damages or defects resulting from normal wear 
and tear (including chips, fading scratches, abrasions or discoloration due to usage or sun exposure), or failure to follow instructions for care and maintenance, fire, flood, and Acts of God. 
This warranty does not include liability for incidental or consequential damages. 

is not responsible for any damages in excess of the retail purchase price of the product under any circumstances. The consumer is responsible for the installation of, removal of, and 

reinstallation of the product. 

Rev. EE112W series 10102017  Page 2

Apply as Dusk to Dawn Automatic SMART Activity Lights

When the light is installed in such: hallway/corridor, stairway, restroom, lobby and any public areas, connect the light with AC power is just 
as easy as replace the existing light system or for new installation project. Make sure the AC power is ON all the time and the light will 

operated as pre-set lighting profile. (

refer: 

Fig. 2 and 7, 8 or 

 Fig. 9 for EE112W only

)

Doppler Motion Detecting Range/Sensitivity Adjustment (Dip switch S1 and S2 Setup)

By Dip switch 1 and 2 to set your preference of the coverage range/sensitivity of motion detection. Unlike other types of motion sensors 
(PIR e.g.), Doppler/Microwave sensor can detect through most nonmetallic blocking obstacles, therefore the movement is detected before 
coming into the area covered with motion sensitivity and the lighting response has no delay. Its average coverage area has a controllable 
range of around 7 to 25 feet diameter when mounted at a height of 8-10 feet. (

refer:   Fig. 7, 8

)

Delay Timer (Dip switch S3 and S4 Setup)

The light can be set to functionally stay ON for any period of time between approx 10 sec. to maximum of 12 min as traditional motion 
activated light, by Dip switch 3 and 4 to select. Any movement detected during this time elapse will re-set the timer. It is recommended to 
select the shortest time for adjusting the Sensitivity detection performance via the walk test, after this testing it is recommended to set 
back to maximum position. (

refer:   Fig. 7, 8

)

Operating Ambient Light Level (Dip switch S5 Setup)

By Dip switch 5 to set with “0” position when the illumination is started depending on the level of environmental darkness at night or with 
“1” position for daylight level and the occupancy area as desired. (

refer:   Fig. 7, 8

)  

Auto Dimming Down as Power SMART Saving & Safety Mode (Dip switch S6 Setup)

, this light can automatically dim down its illumination 

brightness level to fixed 10% of maximum level after the expired delay period when no movement is detected, then it will run up to the 
maximum illumination level when any movement is detected in the coverage area, it is always provide a unique safety and environmental 
friendly lighting profile. (

refer:   Fig. 7, 8

)

Motion Activated as Energy Saving or Traditional Security Sensing Mode (Dip switch S6 Setup)

, then this light can automatically shut OFF after expired delay period (as traditional motion light 

function) when no movement is detected, then it will light-up with MAX brightness illumination when any movement is detected in the 
coverage area. (

refer:   Fig. 7, 8

)

AC Power source: 100-240V/AC 50/60Hz
60 SMD-LED Load: 12W (Max 80W lamp)
LED specifications: T-2835
LED Color: Warm white (3000K), Pure White (5000K)
Lamp Brightness: 950Lm (white); 750Lm (warm)

Protection: Weatherproof IP65, Class2
Light Fixture Material:

Doppler sensor FREQ.: 5.8GHz (WMC)
RF Sensing Power: <0.3mW (WMC)
Detection range: 6feet-25feet x 360° Diameter@6-10feeet High (WMC)
Delay Time Range Setting: 10sec to 12min (WMC)
Ambient Light Level Setting: 50lux (darkness) to 2000lux (Daylight)
Operating Temperature: -4F to +125F
Light Unit Size: 11" (L) x 5" (W) x 4" (H)
Weight: 1.5Lbs 
Approvals: FCC, CE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 