What does state 1/2 and 2/2 mean?
State 1/2 means that you are connected to the Wi-Fi. State 2/2 means that the server.
How do I do a factory re-set?
•
Carry out a soft factory re-set on TouchE3.
Press menu, 7
th
icon house with red dot for 5 secs, scroll down, select general factory default, you will then be presented with a screen that has an X on the left
and a tick on the right, press and hold the tick for 5 seconds.
•
Carry out a hard factory re-set on TouchE3.
1). Turn off for 10 seconds.
2). Switch on until the screen's backlight flicks on (the screen may blink white, or show the normal Touch E3 screen, but it is only the screen lighting up for a
split second that we are interested in).
3). Switch off for 1 second.
4). Repeat steps 2 & 3 a total of 5 times.
5). Switch on and leave for approximately 3 minutes, or until the usual home screen, displaying the time appears.
For the first 2 minutes of this 3 minute period, the screen will turn white, but blink off and back on several times, while the reset process completes. For the last
1 minute, a black screen will appear with first a green progress bar, and then a red progress bar.
After the reset, the software version will have reverted back to 02.01 on the "Menu" screen. So now the software update can be made. Just make sure that all 4
files are on the micro SD card before the update is carried out.
•
Carry out a factory re-set on radiator.
Press and hold OK button until “RFI” shows on the screen then press the right arrow until you see CLR, press and hold OK for 10 seconds. The screen will turn
off and on again and you will be at a screen that reads 00:00
•
Can I reduce the surface temperature?
Yes you can. On the radiator, scroll along to the P icon on the far right. Press Ok to choose your power selection. P1 means a maximum surface temperature of
60 degrees C. P2 means a maximum surface temperature of 75 degrees and P3 means a maximum surface temperature of 90 degrees C.