Table 1-1. SPECIFICATIONS
FREQUENCY COVERAGE:
20 to 600 KHz
GAIN:
57 dB min, ±1.0 variation.
CLASS D LINEAR OUTPUT:
Nominal 500 watts.
INPUT IMPEDANCE
50 ohms, VSWR, 1.5:1 Maximum.
OUTPUT IMPEDANCE:
50 ohms, VSWR, 2.5:1 Maximum
STs STABILITY:
Continuous operation into any load or
source impedance.
DRIVE LEVEL FOR 0.5 KW
-1.72 dBm or 0.2 Vrms
PROTECTION:
Unit will withstand a + 24 dBm input
signal, without damage.
POWER REQUIREMENTS:
110
– 240 VAC
50 / 60 Hz
SIZE:
3 1/4 X 17 X 21.9 inches 8.27 X 43.4 x
55.7 cm.
WEIGHT:
40 pounds 18.2 kg
CONNECTORS:
N-type (power) BNC (sample ports)
OPERATING TEMPERATURE:
0
– 40 C
RACK MOUNTING:
2 U Chassis
Chapter 2 Operation
2.1 INTRODUCTION
The 500S06 RF amplifier is used to amplify the RF level of signal sources in the
20 to 600 KHz. No tuning or any other form of adjustment is required.
The 500S06 produces rated power output at its output connector into 50 Ohms. It
will produce less power at other load impedances. Therefore, although the output
impedance is 50 ohms, the amplifier will work into any load impedance.
On the front of the unit there are BNC connectors for current and voltage
monitors. These monitors provide a scaled down representation of the output
waveform.
Scaling:
Voltage monitor into 50 Ohms 1V = 50 V at amplifier output