Table 1-1. SPECIFICATIONS 

 

FREQUENCY COVERAGE: 

20 to 600 KHz  

GAIN: 

57 dB min, ±1.0 variation. 

CLASS D LINEAR OUTPUT: 

Nominal 500 watts. 

INPUT IMPEDANCE 

50 ohms, VSWR, 1.5:1 Maximum. 

OUTPUT IMPEDANCE: 

50 ohms, VSWR, 2.5:1 Maximum 

STs  STABILITY: 

Continuous operation into any load or 
source impedance. 

DRIVE LEVEL FOR 0.5 KW 

-1.72 dBm or 0.2 Vrms 

PROTECTION: 

Unit will withstand a + 24 dBm input 
signal, without damage. 

POWER REQUIREMENTS: 

110 

– 240 VAC 

50 / 60 Hz 

SIZE: 

3 1/4 X 17 X 21.9 inches 8.27 X 43.4 x 
55.7 cm. 

WEIGHT: 

40 pounds 18.2 kg 

CONNECTORS: 

N-type (power) BNC (sample ports) 

OPERATING   TEMPERATURE: 

– 40 C 

RACK  MOUNTING: 

2 U Chassis 

 
 
 
 

Chapter 2 Operation 

 
2.1 INTRODUCTION 

 
The 500S06 RF amplifier is used to amplify the RF level of signal sources in the 
20 to 600 KHz. No tuning or any other form of adjustment is required.  
 
The 500S06 produces rated power output at its output connector into 50 Ohms. It 
will produce less power at other load impedances. Therefore, although the output 
impedance is 50 ohms, the amplifier will work into any load impedance. 
 
On  the  front  of  the  unit  there  are  BNC  connectors  for  current  and  voltage 
monitors.  These  monitors  provide  a  scaled  down  representation  of  the  output 
waveform. 
 
Scaling: 
 

Voltage monitor into 50 Ohms 1V = 50 V at amplifier output 

 

Current monitor into 50 Ohms 1V = 1 A at amplifier output 

Summary of Contents for 500S06

Page 1: ...on Ltd it is subject to change without notice Dec 2017 Revision A 1 500S06 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with this manual ...

Page 2: ...arts so as to render the unit fully operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cost to be borne by the owner If in our opinion the unit has been damaged by use outside the limits prescribed in this manual or by accident then the warranty shall not be...

Page 3: ...of AM FM SSB pulse and any complex modulation signals within the bandwidth of the amplifier The amplifier has 57 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is protected against failure due to output load mismatch and or overdrive 1 2 INSTRUMENTATION IDENTIFICATION Each amplifier is identified by a serial number tag ...

Page 4: ...4 x 55 7 cm WEIGHT 40 pounds 18 2 kg CONNECTORS N type power BNC sample ports OPERATING TEMPERATURE 0 40 C RACK MOUNTING 2 U Chassis Chapter 2 Operation 2 1 INTRODUCTION The 500S06 RF amplifier is used to amplify the RF level of signal sources in the 20 to 600 KHz No tuning or any other form of adjustment is required The 500S06 produces rated power output at its output connector into 50 Ohms It wi...

Page 5: ...ow ii Connect the output via a 50 ohm coaxial lead and N connector to the load iii Connect the AC supply to the rear of the unit iv Connect the input signal via a 50 ohm coaxial lead and N connector to the input connector Chapter 3 Technical Description 3 1 GENERAL DESCRIPTION The 500S06 is designed to amplify signals by 57 dB in the frequency band of 20 to 600 KHz The signal from the front panel ...

Page 6: ...rive clamp Current and voltage samples are taken from the output and fed to the BNC connectors on the front panel for monitoring purposes The AC supply is fed through an EMI filter to two power supplies that convert the AC to 74 Vdc for the amplifier one DC supply is used for 37 Volt required for the cooling fan and additional DC DC converters to supply the floating 15 V for the gate drivers and 1...

Page 7: ... of wood fiberboard or very strong corrugated cardboard Use ample soft packing to prevent movement Provide additional support for projecting parts to relieve these of unnecessary shock Close the carton securely and seal with durable tape Mark the shipping container FRAGILE to ensure careful handling Chapter 5 Safety Do not attempt to operate this unit with the cover removed High voltages are prese...

Reviews: