IMPORTANT 

 

1. 

The  equipment supplied must not be modified in any way since modifications will 
invalidate intrinsic safety certification, MCA and Lloyds approval. 

 

2. 

Care should be taken during servicing as high voltages may be present on the output 
contacts. 

 

3. 

It is important to note that the ED810 contains four Zener Barriers, type ZB1, which are 
“potted” in epoxy resin.  The Zener Barriers contain fuses which once damaged are not 
replaceable.  The fuses inside the Zener Barrier will blow if even temporary short circuits 
are placed on the sensor wiring thus rendering the Zener Barrier inoperable and not 
repairable.  Great care should therefore be taken to avoid inadvertent short circuits. 

 

4. 

Electronic Devices strongly recommend consultation of the HSE publication EH40, 
which lists the permitted levels of exposure to most toxic gases. 

 
 

ATEX ESSENTIAL SAFETY REQUIREMENTS 
 

The ED810 gas detector, internally mounted Zener Barriers and associated gas sensors are 
ATEX certified Intrinsically Safe and the following important requirements need to be 
followed. 
 
 
1. 

The equipment must only be installed, operated and maintained by trained competent 
personnel. 

 
2. 

This apparatus has been designed in accordance with EN50 014 and EN50 020,  
therefore the apparatus has been designed to meet the fault tolerant requirements of 
Associate Apparatus for Category 'ia'. 

 
3. 

The installation and maintenance must be in accordance with all appropriate 
international, national and local standard codes of practice and site regulations for 
intrinsically safe apparatus. 

 
4. 

The  installation  and  maintenance  must  be  in  accordance  with  the  instructions 
contained in this installation and maintenance manual. 

 
5. 

Access to the circuitry must not be made during operation. 

 
6. 

This product is an associated electrical apparatus and must not be installed in the 

 

hazardous area without the provision of further certified hazardous area protection. 

 
7. 

The product must not be subjected to mechanical and thermal stresses in excess of  
those permitted in the certification documentation and the instruction manual.  If 
necessary the product must be protected by an enclosure to prevent mechanical 
damage. 

 
8. 

The product must not be installed in a position where it may be attacked by 
aggressive substances. 

 
9. 

The product must be protected from excessive dust by an enclosure etc. 

 
10. 

The product can not be repaired by the user and must be replaced by an equivalent 
certified product. Repairs should only be carried out by the manufacturer or approved 
service centre. 

Summary of Contents for ED810

Page 1: ...NDUCTOR 7 CALIBRATION HEAD ELECTRONICS 8 DECLARATION OF CONFORMITY 10 ED810 EC TYPE EXAMINATION CERTIFICATE 13 ZB EC TYPE EXAMINATION CERTIFICATE 18 ELECTRONIC DEVICES LIM ITED ENIGM A HOUSE ENIGM A BUSINESS PARK M ALVERN W ORCESTERSHIRE W R14 1GD ENGLAND TELEPHONE 44 0 1684 891500 FACSIM ILE 44 0 1684 891600 EM AIL sales electronicdevice dem on co uk W EB SITE www electronicdevice dem on co uk E ...

Page 2: ...personnel 2 This apparatus has been designed in accordance with EN50 014 and EN50 020 therefore the apparatus has been designed to meet the fault tolerant requirements of Associate Apparatus for Category ia 3 The installation and maintenance must be in accordance with all appropriate international national and local standard codes of practice and site regulations for intrinsically safe apparatus 4...

Page 3: ...on should be given to the Hazardous Area common connection terminal This should normally be connected to a good quality earth suitable for intrinsically safe equipment However this terminal is internally connected to 0V VE of the DC supply and on insulated return installations may produce an earth fault Isolation can be provided by using a DC DC inverter or if mains is available a suitable linear ...

Page 4: ...ld not allow greater than 0 25V drop along its length when carrying 1A plus current required for ancillary equipment connected Twin core double insulated 15A cable is normally adequate The main DC input fuse is normally 2A rated but may be increased to 3A allowing for ancillary equipment External fusing may be necessary and should be considered The DC supply should not deviate by more than 25 of t...

Page 5: ... functions A fused 12V or 24V supply is available on terminal 2 for the operation of low power sounders and beacons the installation engineer must provide the links to provide the required functions Remember any sounders or beacons located in the Hazardous Area must be certified Flameproof or Intrinsically Safe if fed via an external zener barrier contact EDL for further information FIG 2 FIG 3 Re...

Page 6: ...r suitable for the detection of various toxic gases Many different electrochemical cells are available and EDL should be consulted to advise on correct sensor type The EDS P IS Transmitter is a intrinsically safe junction box complete with head electronics and catalytic pellistor gas sensor suitable for the detection of flammable gases Contact EDL for advice on correct sensor type Siting The senso...

Page 7: ...pproximately 30minutes A hidden switch is located to the left of the reset switch Pressed through the front panel using a small screwdriver all Alarms are Isolated and the Fault Buzzer sounds Operate the hidden switch to the right of the Reset switch keeping it pressed for several seconds and all Alarms will be returned to the operational state and the Fault Buzzer will silence CALIBRATION Before ...

Page 8: ...our low alarm ensure the calibration of the EDSC Transmitter using the EDSC calibration instructions Whilst the EDSC is giving the correct output go to the ED810 control unit and adjust the A1 located under the A1 light accessed through the front panel potentiometer until the A1 light just illuminates Rotating clockwise increases sensitivity until the A1 light just illuminates if the light comes o...

Page 9: ... illuminates if the light comes on prematurely wind anticlockwise whilst continuously pressing the reset switch until the light goes out and then clockwise until it just illuminates 3 Back at the EDS P again using the Zero adjustment potentiometer on the EDS P rotate clockwise until the 100 lamp is just illuminated or 0 5V is measured on the O P terminal w r t 0V 4 Go to the ED810 Control unit and...

Page 10: ...ED810 INSTRUCTION MANUAL 24 06 11 10 ...

Page 11: ...ED810 INSTRUCTION MANUAL 24 06 11 11 ...

Page 12: ...ED810 INSTRUCTION MANUAL 24 06 11 12 ...

Page 13: ...ED810 INSTRUCTION MANUAL 24 06 11 13 ...

Page 14: ...ED810 INSTRUCTION MANUAL 24 06 11 14 ...

Page 15: ...ED810 INSTRUCTION MANUAL 24 06 11 15 ...

Page 16: ...ED810 INSTRUCTION MANUAL 24 06 11 16 ...

Page 17: ...ED810 INSTRUCTION MANUAL 24 06 11 17 ...

Page 18: ...ED810 INSTRUCTION MANUAL 24 06 11 18 ...

Page 19: ...ED810 INSTRUCTION MANUAL 24 06 11 19 ...

Page 20: ...ED810 INSTRUCTION MANUAL 24 06 11 20 ...

Page 21: ...ED810 INSTRUCTION MANUAL 24 06 11 21 ...

Page 22: ...ED810 INSTRUCTION MANUAL 24 06 11 22 ...

Page 23: ...ED810 INSTRUCTION MANUAL 24 06 11 23 ...

Reviews: