21
TB3
TB1
TB2
TB4
COM
N
HI
SOLENOID
COMMON
(120 VAC N)
120 VAC 60 HZ
INPUT POWER
SW HI NEUT
PULSE OUTPUT
Lower Board
TB1
Upper Board
H2O OFF ADJ ON ADJ
0
4
1
2
3
4
5
6
4-20 mA
INPUT FROM
Δ
P
REMOTE CONTROL
120 VAC - INPUT
HOLD-OFF
120 VAC - INPUT
+
-
HI
NEUT
HI
NEUT
SW 1
ON
OFF
40
1 2 3 20
A
20
120 VAC SWITCHED
OUTPUTS TO
SOLENOIDS
(120 VAC HI)
E40 MH1, 40 POSITION TIMER
4-20
M
A MODE
PHYSICAL DIM:
9" X 11" w
MOUNTING DIM:
8.5" X 10.5"
40
PROGRAM WIRE
EDI
HEWITT, NJ 07421
NOTES:
1. The Timer switch, SW1, must be in the OFF
position. The DP Transmitter's 4-20
M
A
signal automatically adjusts the Timer OFF Time.
2. Set the Timer H
2
O control to the desired
working pressure
3. The program wire should be placed in the desired
position for the numbers of outputs required.