background image

VERIFICATION OF SELECTED PROGRAMS

To visualize or modify selected programs press 

M

 to position the cursor 

PROG

.  The cursor above 

the day of the week will begin to scroll from 1-7, displaying the program set up for each day of 

the week.  In this condition you can modify the set program by pressing the 

+

 or 

 buttons and 

repeating the operations described above (points 2 – 5).   

To exit the visualization of programs, press 

M

MODIFYING HOURS OF PROGRAMS  P1 E P2

If the factory set hours of the programs  

P1

 e 

P2

 are not satisfactory, you can modify them. 

e.g. modifying 

P1

 hours:

1.

 Pressing the 

M

 button, position the cursor 

on 

PROG

.  The  cursor  above  the  day  of  the 

week will begin to scroll from 1-7, displaying 

the program set up for each day of the week.                                      

2.

 Press  

+

 or

 –

  and select  

P1

.  

P1

 begins to 

flash.

Hold down  

M

 for 6 seconds.

3.

  the  starting  hour  of 

  P1

  (  6:00)  begins  to 

flash.   Press 

+

 or 

 to modify the starting hour. 

Each press of 

+

 or 

 will vary the hour by 30 

minutes. 

Press 

M

 to set the hour.

Sira Onice - INSTRUCTIONS FOR USE

English

11

Summary of Contents for Onice 1000

Page 1: ...nice 1000 1600 2000 Electron www siragroup onice it graphic www caleidos ws Italiano English Français Deutsch Español Português 中文 Русский ...

Page 2: ... AND SIZES ELECTRICITY SUPPLY INSTALLATION INSTRUCTIONS FOR UNINSTALLING THE RADIATOR INSTRUCTIONS FOR USE MAINTENANCE GUARANTEE DISPOSAL TECHNICAL CHARACTERISTICS Pag 01 Pag 02 Pag 02 Pag 02 Pag 03 Pag 06 Pag 06 Pag 17 Pag 17 Pag 18 Pag 18 Sira Onice INDEX English ...

Page 3: ...This radiator is to be used exclusively by adults Children or others using the radiator must be supervised Leave at least 50 cm of space between the radiator and any inflammable objects For any cleaning or maintenance operations the radiator must be turned off and unplugged The materials used in packing this radiator are recyclable It is recommended to dispose of this material in an appropriate ma...

Page 4: ...rent corresponds to that indicated on the radiator This radiator is in Insulation Class II and therefore no ground connection is necessary Single phase supply 230 V 10 10 50Hz Protection grade IP24 Respect the color of the wires for the connections Brown phase Blue neutral Nero pilot wire Isolate the pilot wire if it is not in use Sira Onice COMPLIANCE DECLARATIONS RANGE AND SIZES ELECTRICITY SUPP...

Page 5: ...at least 15 cm from any obstacle walls furniture shelves etc CORRECT POSITIONING OF RADIATOR Unpack the radiator and place it carefully on the ground using the polystyrene as protection Make sure that the radiator and cords have not been damaged during transport If damaged do not use the radiator During installation verify that the radiator is not plugged in Verify that the home voltage correspond...

Page 6: ...loor In this way the radiator will be positioned at the correct height 2 Using the template use a pencil to mark the position of the 4 holes indicated for your model of radiator Drill 4 holes in the wall with a diameter of 10mm and a depth of 50 55mm fig 2 Sira Onice INSTALLATION TEMPLATE fig 2 TEMPLATE 0 10x55mm 0 10x55mm 0 10x55mm 0 10x55mm FLOOR WALL fig 3 English 04 ...

Page 7: ...ure the space between the radiator and the wall it should be 2 5 mm 5 Observing from above the space between the radiator and the wall fig 6 verify that the radiator is in the correct position to be inserted into the two plastic clips of the brackets 6 Exert pressure on the bottom part of the radiator until you hear a click fig 7 At this point installation is terminated Sira Onice INSTALLATION LEF...

Page 8: ...pulling out at the bottom until radiator is released fig 8 INSTRUCTIONS FOR USE Sira Onice INSTRUCTIONS FOR UNINSTALLING THE RADIATOR INSTRUCTIONS FOR USE Eco Mode Standby Mode Anti freeze Mode Comfort Mode Time and Date Regulation Automatic Mode Programing Mode Keyboard locking Indicates selected temperature Days of the week 1 monday 2 tuesday 7 sunday Keys regulation of selected temperature Heat...

Page 9: ... the display is regulation of time and date mode In this mode it is possible to regulate the time and date in order to program the functioning cycle of the radiator 1 Setting the time Press the or buttons to set the hours hours will flash Select by pressing M Hours stop flashing To rapidly scroll the hours hold down or 2 Setting the minutes Press the or but tons to set the minutes minutes will fla...

Page 10: ...e minutes the cursor is situated above no 1 Monday and begins to flash Select the day by pressing or and set by pressing M cursor stops flashing 4 To exit the time and date regulation mode press M Sira Onice INSTRUCTIONS FOR USE English 08 ...

Page 11: ... 00 to 6 00 Comfort P3 the radiator functions in Comfort mode 24h 24h for the day of the week selected Initially the temperature in Comfort mode is set at 20 C for everyday of the week You can vary the temperature level in the Comfort mode to your pleasure see temperature regulation in Comfort mode Economy P4 the radiator functions in Economy mode 24h 24h for the day of the week selected Initially...

Page 12: ...for each day of the week until day 7 Sunday 5 Once you have selected the program until the last day of the week Sunday and pressed M the cursor above the days of the week will begin to scroll from 1 7 displaying the set programs 1 Pressing button M position the cursor on PROG at this point the cursor above the day of the week will begin to scroll from 1 7 displaying the program set up for everyday...

Page 13: ...s press M MODIFYING HOURS OF PROGRAMS P1 E P2 If the factory set hours of the programs P1 e P2 are not satisfactory you can modify them e g modifying P1 hours 1 Pressing the M button position the cursor on PROG The cursor above the day of the week will begin to scroll from 1 7 displaying the program set up for each day of the week 2 Press or and select P1 P1 begins to flash Hold down M for 6 secon...

Page 14: ...described above 4 The final hour of P1 22 00 begins to flash Press or to modify this hour Each press of or will vary the hour by 30 minutes Press M to set the hour P1 is now modified automatically with the new hours set for each day of the week Sira Onice INSTRUCTIONS FOR USE English 12 ...

Page 15: ...h an active pilot wire where present Temperature regulation in comfort mode Pressing M position the cursor on Comfort mode and select the desired temperature by pressing or The temperature can be set from 10 30 C with 0 5 C intervals ECONOMY MODE The Economy mode permits the radiator to function economically and corresponds to the Comfort temperature less 3 5 C 16 5 To change the default differenc...

Page 16: ...the heating while maintaining the radiator plugged in indicated on display ANTIFREEZE MODE The Antifreeze mode protects your home prohibiting the ambient temperature from going below 7 C To change the default Anti freeze temperature please consult the section on Advanced Regulation English 14 ...

Page 17: ...nt modes of radiator functioning can be activated at a distance Radiator functioning by means of remote control is possible only in the Auto mode In other modes Comfort Economy etc signals from the remote are not received Commands by remote control always has priority over the manual setting of individual radiators Temporary cancellation of a command received from a remote control device When nece...

Page 18: ...ermanent backlighting Press to go from L1 to L2 and vice versa Press M to set your selection Temporary Interruption of Power Supply In cases of temporary interruption of the power supply the radiator will automatically reset its preexisting values The array of regulation parameters such as the clock are saved When power returns all preceding values will be reestablished Sira Onice INSTRUCTIONS FOR...

Page 19: ...products depending on the discretion of the manufacturer The guarantee is valid only if Installation standards as well as warnings and recommendations found in this manual are respected There are manufacturing defects present when the product is sold noted within two years of the sales date The guarantee is not valid if There are defects present caused by uses of the product other than those speci...

Page 20: ...n Using recycling centers for the disposal of electronic helps to protect health and the environ ment and permits salvaging its components with a consequent savings of energy and natural resources The symbol below represents a trash container not to be used for such disposal TECHNICAL CHARACTERISTICS Voltage 230VAC 10 20 50 hz Safety compatible with Class II in compliance with EN60335 1 EN60335 2 ...