background image

Fault indicator (8) illuminates with 
steady light: 

There is a system fault in the charger. 

 

Switch off the charger - switch (1) in 
position „0“ - and contact the 
authorized workshop or your expert 
dealer. 

 

5.0 Technical 

data 

 
Mains voltage 

230 V 

Mains frequency 

50/60 Hz 

Nominal voltage 
 

12 V and 24 V 
lead-acid 
batteries 

Constant voltage   

2.4 / 2.35 V/cel 

Charging current 

30 A and 15 A 

Charging characteristic   

IUoU 

Protection type 

IP 21 

Metal housing 

 

(W x H x D in mm) 

135 x 260 x 275 

Weight 5,2 

kg 

Length of charging 
cable (incl. clips) 

 
2 m 

Length of mains cable 

1.5 m 

 
Subject to technical changes without prior 
notice 

 

 

 

 
 
 
 

The HS 12/24-30 Battery Charger 
complies with the requirements of the 
automotive industry and in particular 
fulfils DIN EN 60335-2-29 and IEC 801. 
 
 
 
 
 

 

-  5  - 

 

 

Contents 

1.0 Safety 

notes 

2.0  Description of the unit 
3.0 Startup 
3.1 Charging 
3.2 Backup 

mode 

3.3  Floating mode/trickle charge 
4.0  Fault indication and 

troubleshooting 

5.0 Technical 

data 

 

1.0 Safety 

notes 

 

Caution! Explosive gases are 
generated during charging of 
batteries! 

 

Only charge batteries in well 
ventilated areas. Explosion hazard 
on account of generation of 
oxyhydrogen gas! 

 

Avoid all forms of fire, naked light 
and sparking! 

 

Wear protective goggles! 

 

If acid splashes on to skin or 
clothing, wash off immediately 
with generous quantities of water! 

 

Caution! 
If there is a pungent smell of gas, 
acute explosion hazard is present! 

 

Do not switch the charger off! 

 

Do not remove the charging clips! 

 

Thoroughly ventilate the area 
immediately! 
After adequate ventilation, switch 
the charger off! 

 

Check the battery! 

 

Protect the charger from damp and 
wet! 

 

Install the charger such that the air 
outlet is free! 

 

Ensure stable location of the 
charger! 

 
 
 

-  2  - 

Electrical safety:

 

Mains and charging cable 

must be in perfect 

condition

. If these cables are damaged in 

any way, contact the authorized workshop or 
your expert dealer. 

 

 

Before start-up of the unit read the 
operating instructions carefully. 
Always operate the charger according to 
these instructions. 

 

2.0  Description of the unit 

 

With the battery charger 

HS 12/24-30

 (in the 

following „

HS

“) all 12- and 24V wet batteries 

(also lead calcium), maintenance-free gel 
batteries, fleece batteries and  
AGM-batteries can be charged. 

 

The required voltage can be selected with the 
„charging voltage switch“ (1). 
 

 
The unit is switched on, the lower yellow 
LED (0%) flashes: 

Either there is no battery connected or there is 
no contact with the battery. 
 
With changeover switch (5) you choose the 
battery type: 
2.4 V/cell for wet batteries / AGM-batteries 
2.35 V/cell for gel batteries  
 
The microprocessor of the 

HS 

controls the 

charging current according to the discharge 
degree of the battery and automatically 
provides optimum charging. 

Working on the open 
unit may only be done 
by an authorized and 
skilled expert! 

 

Reviews: