TABLE OF CONTENTS 

 
 
1.0  

Introduction      ………………………………………………………..… 

 

2.0 

Calibration curves       ……………….………………………………..… 

 

3.0 

Design of the device        ……………………………………………….. 

 

3.1 

Menu 

3.2 

Keypad symbols 

 

4.0 

Most common reasons for miss readings       ……….……………..… 

 

5.0 

Device maintenance instructions       ………………………………..… 

 

6.0 

Changing batteries       ………………………………………………..… 

 

7.0 

Determination of the material moisture       …………………………… 

 

8.0 

Technical data        …………………………………………………….… 

10 

 

10.0  Warranty       ……………………………………………………………… 

11 

 
 

Summary of Contents for FS2

Page 1: ... 1 0 Introduction 2 2 0 Calibration curves 4 3 0 Design of the device 5 3 1 Menu 3 2 Keypad symbols 4 0 Most common reasons for miss readings 8 5 0 Device maintenance instructions 8 6 0 Changing batteries 9 7 0 Determination of the material moisture 9 8 0 Technical data 10 10 0 Warranty 11 ...

Page 2: ...ust be authorized by Electromatic in advance with all repacking and shipping expenses to the address below to be borne by the purchaser THE FOREGOING WARRANTY S IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL ...

Page 3: ...app 1 3 kg with batteries Degree of protection IP 40 Scope of supply Plastic case Digital scale 1000g Measuring cup 0 5 litre 4 x 1 5Volt AA Alkaline Batteries Electromatic Equipment Co Inc 3 8 Fill up the measuring device with the sample material The filling needs to be done slowly and constantly to ensure reproducible results 9 The display shows the measuring result 10 To save the results in the...

Page 4: ... device Make sure the position of the battery poles is correct 4 Press down the batteries and close the cap 7 0 DETERMINATION OF THE MATERIAL MOISTURE The principle is a comparison measurement with the drying out method according to DIN 10350 1967 09 Take the measured sample and weigh it Dry it out in an oven and weigh it again Following formula can be taken to determine the absolute moisture Note...

Page 5: ... calibration curve Wrong fill quantity Fill exactly the right weight 1 0 g in the measuring chamber Wet or mouldy material Frozen measuring material 5 0 DEVICE MAINTENANCE INSTRUCTIONS To provide a long lives of your device please do not expose it to strong mechanical loads or heat e g dropping it or direct sunlight exposure Clean your device using a dry cloth The measuring chamber needs to be cle...

Page 6: ...t Log All Logs Clear Send Logs Manual Logs Clear Logs Options Date Time Language Unlock C F Password Reset Materialcalib Status Electromatic Equipment Co Inc 7 3 2 Keypad symbols Measuring window Rolling Menu Power ON OFF Switch upper Switch lower Save Hold Watch the measuring rows Suppliers data can be added Menu Enter Switch upper Switch lower Exit Enter numbers Enter letters Next or right Left ...

Page 7: ...FS2 GRAIN MOISTURE METER OPERATING INSTRUCTIONS Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net ...