background image

O P E R A T I N G

M A N U A L

Digital

T

ENSION

M

ETER

CHECK

LINE

®

BY ELECTROMATIC

Model DTMB

Distributed by:

 ABQ Industrial LP USA

Tel: 

+1 (281) 516-9292 / (888) 275-5772  

eFax:

 +1 (866) 234-0451

 

Web: 

http

s

://www.abqindustrial.net  

E-mail: 

[email protected]

Summary of Contents for CHECK LINE DTMB-1K

Page 1: ...oduct at ELECTROMATIC s option except where unauthorized repair disassembly tampering abuse or misapplications has taken place as determined by ELECTROMATIC All returns for warranty or non warranty repairs and or replacement must be authorized by ELECTROMATIC in advance with all repacking and shipping expenses to the address below to be borne by the purchaser THE FOREGOING WARRANTY IS IN LIEU OF A...

Page 2: ...ncing needle condition found on most mechanical tension meters To set or change the Display Update Rate refer to Configuring Dip Switch Settings Section 5 30 A built in memory system is provided which permits storage of the maximum minimum and peak values occurring during a measuring interval These values can be recalled to the display for viewing 23 Specifications Measuring Principle Strain gauge...

Page 3: ...MB OVERVIEW Model DTMB 200 DTMB 500 DTMB 1K DTMB 2K DTMB 2 5KB DTMB 5KB DTMB 10KB DTMB 20KB DTMB 20KB Tension Range grams 0 1 200 0 0 1 500 0 50 1000 200 2000 250 2500 500 5000 1 00 10 00 Kg 2 00 20 00 Kg 50 KB Accuracy 1 0 or better 1 5 or better Outer Roller Dist c c 38 mm 38 mm 38 mm 38 mm 100 mm 100 mm 100 mm 200 mm 200 mm 22 10 00 SPECIFICATIONS 37 153 60 38 65 76 Outer roller spacing c c 2 5...

Page 4: ... Description of Functions 3 00 DESCRIPTION OF MEMBRANE KEY FUNCTIONS STORE RECALL POWER EXIT RECALL STORE POWER EXIT RECALL When the units of measure are changed to grams the gf indicator will momentarily flash on and then turn off Otherwise the lb or oz indicators will be shown Changes units of measure from grams or Kg to pounds or ounces and back again each time this key combination is pressed S...

Page 5: ...MB into the measuring position and perform a Gravity Correction procedure Zero Press the and keys simultaneously and hold until the display shows 0 or 0 0 POWER EXIT POWER EXIT RECALL 20 8 23 Low Battery When the BATT indicator appears on the display the batteries are low Data will be lost when the batteries are removed 8 30 Options 8 31 Ultra High Speed Roller Assemblies For line speeds up to 5 0...

Page 6: ... 8 10 Turning Power On Off Turn Power On Press key Turn Power Off Press and the key for five 5 seconds Note DTMB will power off automatically after 90 seconds of inactivity except for the following instances Memory Mode configured for Standard NAPO No Auto Power Off When AC Adapter is used 8 20 LCD Display Indications and Codes 8 21 Over Range Display When a displayed value is flashing on off this...

Page 7: ...tion is not adequate the accuracy of the DTMB can be increased further by ordering a Special Calibration using a calibration sample supplied by the user Refer to Special Calibration Section 7 30 7 20 LCD Display Indications and Error Codes 7 21 Over Range Display When a displayed value is flashing on off this indicates that this reading is higher than the maximum range of the unit The accuracy of ...

Page 8: ...tly to insure that the gauge continues to perform within factory specifications Implementing a periodic calibration check will help identify when and if the gauge goes out of calibration due to unreported damage overload or other unknown reason To check the calibration 1 Suspend a known weight W from the process material in either a vertical or horizontal direction best simulating the orientation ...

Page 9: ...lt in microprocessor uses this calibration data with a complex formula to calculate a calibration curve which takes into account the material thickness and orientation of use The factory calibration works well in most cases However if the process material to be measured differs significantly from the Factory Calibration Standard Materials see table below or if the application requires the highest ...

Page 10: ...actory Setting Standard N A P O Standard Memory with No Auto Power Off POWER EXIT Slide Guide Plate Thumbpiece 15 6 11 Viewing Data in Standard Memory To view data stored in Standard Memory press the key The following will be displayed when the key is pressed repeatedly Each time the key is pressed the displayed value will change Press the key at any time to exit the Recall Mode 6 12 To Clear All ...

Page 11: ...one of two modes Standard Memory or Standard Memory With No Auto Power Off The data stored in the Standard Memory can be recalled to the display for viewing 6 10 Standard Memory Mode The DTMB takes 62 tension measurements per second and displays the aver age of these measurements over a user selected Display Update Rate of 0 5 1 2 or 4 seconds The Standard Memory system checks each displayed value...

Page 12: ...When using the three roller principle of tension measurement an increase in material diameter will result in an increased tension reading even when the line tensions are unchanged The DTMB is supplied with a proprietary Thickness Compensation system which automatically shifts the outer rollers to compensate for this effect Additionally the Thickness Compensator measures the material diameter with ...

Page 13: ... A N U A L Digital TENSION METER CHECK LINE BY ELECTROMATIC Model DTMB Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net ...

Reviews: