Your power unit does not require the assembly of a muffl er. Your CVS 
has the muffl er installed internally. You may however desire to exhaust 
the air outside. In this case you will need to attach the exhaust adapter. 
This will convert the size of the exhaust to the diameter of the central 
vacuum pipe.

Refer to page 8 - Image 5

•  Place the power unit in order to make the exhaust pipe as short as 

possible. Exhausts should be limited to no longer than 16.5ft (5m).

•  Keep in mind that you may need space on the sides of your 

central unit to be able to access the dirt receptacle.

  Refer to page 8 - Image 6

•  Align the power unit intake fi tting to the main trunk line projecting from the 

wall. 

DO NOT GLUE. 

Attach the exhaust pipe to the motor exhaust if 

exhausting outdoors. Make sure the exhaust pipe is as short as possible. 

NOTE:

 Mount central power unit at least 12in (30cm) from the ceiling 

and any adjacent wall, at least 27.5in (70cm) from the fl oor and within 6ft 
(1.8m) of an electrical outlet. Review any local regulations that may apply. 

Refer to page 8 - Image 2

WARNING

Do not block the hood ventilation openings on the top of the central 
power unit. Lack of ventilation will cause the motor to overheat.

WARNING

Do not locate the central power unit in a high temperature area where it 
is inaccessible for example, an attic or crawl space.

For the ultimate in air control you have model ZCV920H. This model 
features a True HEPA fi lter and may be included with your choice of 
power unit or can be purchased from an authorized dealer/distributor. 
Simply attach the true HEPA fi lter as shown. 

Refer to page 8 - Image 7

SYSTEM TEST

Be certain to comply with local electrical codes and regulations. Plug 
the unit into a regular electrical outlet. You are now ready to check the 
installation of the unit: 

•  Be sure the fi lter is properly installed in the power unit. 

•  Be sure the dirt receptacle is properly secured to the power unit. 

•  Plug the hose into each inlet valve to be sure the electrical 

contacts operate properly. 

•  Check each inlet valve for air leaks. 

•  Check each pipe connection for air leaks.

Refer to page 8 - Image 8

HOW TO USE CENTRAL VACUUM SYSTEM

Your central vacuum system is controlled by a switch on your hose. 
Simply insert the hose into the valve and turn the switch to the on position. 
This will start the power unit and the fl ow of air. 

When you are fi nished, turn the switch on the hose to the off position 
and remove the hose from the inlet valve. When unplugging the hose, 
hold the inlet cover open for a few seconds to allow suction to decrease 
thus, protecting the inlet valve seal. 

Refer to page 8 - Image 8

LED INDICATIONS

 - OPTIONAL DEPENDING ON MODEL

You machine may be equipped with some or all of the indicators listed below. 

Refer to page 8 - Image 9

On/Off 

Motor Fault 

Dirt Receptacle Full 

Reset

Your power unit is equipped with a multi color LED panel. This LED 
panel will provide you with necessary information on your power unit’s 
performance, maintenance and diagnostics. Below are descriptions 
of the different messages the power unit will provide.

NORMAL OPERATION

When the power unit is OFF and considered to be in standby mode the 
LED button will be RED. 

When the power unit is ON and in use the LED will be GREEN. When 
the motor fault light is ON see further description below. When the dirt 
receptacle light is ON, empty dirt receptacle and press the RESET 
button, and hold for 10 seconds.

When you LCD power unit is in standby mode the four white lights on your 
LCD unit will light up in sequence and alternate moving from left to right 
then reversing right to left. This pattern will repeat continuously and is an 
indication that your power unit is ready for use and functioning properly.

MOTOR FAULT

In the case of a blown fuse or disconnected motor wire and the power 
unit is not functioning the ON/OFF button will be constantly GREEN In the 
case of an over current shutdown, the ON/OFF button will be fl ashing RED, 
the GREEN light will on and off rapidly and the MOTOR FAULT light will be 
AMBER and turn on and off rapidly. This fault will reset automatically in 
15 seconds if the low volt connection is OFF at the hose. 

In the case of a continued over current and the low volt connection is 
ON and the hose the ON/OFF button will constantly be RED, the GREEN 
light will fl ash slowly and the MOTOR FAULT will slowly fl ash AMBER.

In the unlikely event of a bad frequency received by the power unit the 
power unit will not start and the ON/OFF button will remain constantly RED. 
In the case of a high line voltage received by the power unit the ON/OFF 
button will alternate between RED and GREEN three times- pause briefl y 
– alternate between RED and GREEN three times – long pause- and then 
repeat. This will continue until the line voltage returns to the correct level.

LCD SCREEN

 - OPTIONAL

Refer to page 8 - Image 8

ZCV920H

In the main screen of the LCD, the Electrolux logo will appear. This logo 
may scroll from side to side to avoid the image ingraining itself onto the 
LCD Display. You will see the logo when the power unit is not in use.

The button that best lines up with the Power symbol on the screen can 
be used to activate the unit. Press this button to toggle the unit on/off. 
The unit may also be activated from any installed inlet. 

Summary of Contents for ZCV900

Page 1: ...central vacuum system owners manual Type K 460509 ZCV900 ZCV910 ZCV920H electrolux sistema de aspiradora central oxygen système central d aspiration oxygen electrolux manual del usuario Tipo K manuel d utilisation Type K ...

Page 2: ...rking as it should has been dropped damaged left outdoors or dropped in water return it to a service center Connect to a properly grounded outlet only refer to grounding instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or cord...

Page 3: ...d on the control panel or motor hood For prompt and complete service information always refer to these numbers when inquiring about service WARNING Non observance of the safety directions may result in bodily harm PRODUCT DIMENSIONS Refer to page 8 Image 1 WASTE OF ELECTRIC AND ELECTRICAL EQUIPMENT WEEE This symbol on the product or on its packaging indicates that this product may not be treated a...

Page 4: ...ction to decrease thus protecting the inlet valve seal Refer to page 8 Image 8 LED INDICATIONS OPTIONAL DEPENDING ON MODEL You machine may be equipped with some or all of the indicators listed below Refer to page 8 Image 9 On Off Motor Fault Dirt Receptacle Full Reset Your power unit is equipped with a multi color LED panel This LED panel will provide you with necessary information on your power u...

Page 5: ...cle status life monitor measure or most recent recorded power level To scroll through these features simply push the button corresponding with the right pointing arrow symbol The next screen you will see will be the Life Meter Scroll right further and you will find Bucket Status Yet another scroll will show you last recorded performance levels of the power unit using the Performance Meter on the In...

Page 6: ...ose into any inlet valve If there is no suction through the hose after connecting at a couple of inlets the blockage is in the hose To clear the hose obstruction insert a blunt instrument into the hose garden hose wood dowel You can also attempt to reverse the suction through the hose to dislodge the blockage Refer to page 8 Image 12 and 13 If there is one inlet valve without normal suction and yo...

Page 7: ...eriod stated above Electrolux Central Vacuum Systems shall not be responsible for such service unless provided by an authorized Electrolux Dealer utilizing authentic Electrolux replacement parts This warranty does not apply to loss or damage resulting from at Electrolux Central Vacuum System s sole opinion normal wear and tear commercial use neglect abuse acts of God accidents improper installatio...

Page 8: ...otor Status Empty Dirt Receptacle Reset LCD Screen Max 16 5 5 m Min 27 5 70 cm Maximum 6 1 8 m from outlet Min 12 30 cm Min 12 30 cm Min 12 30 cm 15 380mm 4 100mm 18 465mm 40 5 1032mm 19 5 495mm 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 9: ...onecte el aparato solamente a un tomacorriente debidamente puesto a tierra consulte las instrucciones de conexión a tierra No utilice extensiones o tomacorrientes con una capacidad de conducción de corriente inadecuada Apague todos los controles antes de desenchufar el sistema No tire del cable para desenchufarlo Al desenchufar sujete el enchufe no el cable No manipule el enchufe ni el cable con l...

Page 10: ...panel de control o en la cubierta del motor Para obtener información completa de servicio de manera rápida utilice estos números cuando busque obtener servicio ADVERTENCIA Hacer caso omiso de las instrucciones de seguridad puede ocasionar daños físicos DIMENSIONES DEL PRODUCTO Consulte la página 15 imagen 1 DESECHOS DE EQUIPOS ELÉCTRICOS Y ELECTRÓNICOS WEEE Este símbolo que figura en el producto o ...

Page 11: ...do protegerá la junta de la válvula de entrada Consulte la página 15 imagen 8 INDICACIONES DEL LED OPCIONAL SEGÚN EL MODELO Su máquina puede estar equipada con todos o algunos de los indicadores que se muestran a continuación Consulte la página 15 imagen 9 La unidad eléctrica está equipada con un panel LED multicolor Este panel LED le ofrecerá la información necesaria sobre el rendimiento mantenim...

Page 12: ...l estado del medidor de vida útil o el nivel de energía registrado más recientemente Para desplazarse por estas funciones solamente tiene que pulsar el botón que corresponda con el símbolo de la flecha que apunta hacia la derecha La próxima pantalla que aparecerá será la del medidor de vida útil Desplácese más hacia la derecha y verá el estado del depósito Desplácese una vez más y verá los niveles ...

Page 13: ...ctamente cerrada RETIRE LAS OBSTRUCCIONES DE LOS TUBOS Obstrucción de la manguera Conecte la manguera a cualquier válvula de entrada Si la manguera no succiona pese a haberla conectado a diversas entradas la manguera está obstruida Introduzca un elemento sin filo en la manguera para limpiarla como una manguera de jardín o una espiga de madera También puede intentar revertir la succión a través de l...

Page 14: ...el período de garantía que se indica arriba Electrolux Central Vacuum Systems no se hace responsable por tal servicio a menos que sea proporcionado por un distribuidor autorizado Electrolux usando piezas Electrolux auténticas Esta garantía no se aplica a pérdidas o daños causados según la opinión de Electrolux Central Vacuum Systems por el uso y desgaste normal uso comercial negligencia abuso hech...

Page 15: ...es Mín 12 pulgadas 30 cm Mín 12 pulgadas 30 cm Mín 12 pulgadas 30 cm 15 pulgadas 380 mm 4 pulgadas 100 mm 18 pulgadas 457 mm 40 5 pulgadas 1 028 mm 19 5 pulgadas 495 mm Botones LED Restablecer Encendido Apagado On Off Estado del motor Limpieza del contenedor de polvo 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 16: ... centre de service Branchez le dans un prise de courant correctement mise à la terre seulement consultez la section Instructions pour mise à la terre N utilisez pas de cordons de rallonge ou de prise dont l intensité de courant admissible n est pas acceptable Fermez toutes les commandes avant de débrancher Ne débranchez pas en tirant sur le cordon Pour débrancher tirez la fiche pas le cordon Ne man...

Page 17: ...FORMATION CONCERNANT L ENTRETIEN Les instructions contenues dans ce manuel servent de guide pour l entretien de routine Pour plus d information communiquez avec votre détaillant ou distributeur autorisé local PLAQUE SIGNALÉTIQUE Le type et les numéros de modèle et de série sont indiqués sur la plaque signalétique qui se trouve sur le panneau de commandes ou sur le capot du moteur Pour obtenir rapi...

Page 18: ...our un contrôle ultime de la qualité de l air optez pour la système ZCV920H La série 650 est dotée d un filtre HEPA authentique et peut être intégrée à l unité motrice que vous choisissez ou peut être achetée chez un détaillant ou un distributeur autorisé Vous n avez qu à fixer le filtre HEPA authentique tel que montré Voir à la page 23 Image 7 VÉRIFICATION DU SYSTÈME Assurez vous que votre installat...

Page 19: ...rogression de la performance apparaîtront Lorsqu une unité motrice fonctionne normalement les 4 barres de performance devraient être allumées S il y a constamment moins de 2 barres vous devriez vérifier quel est le problème 1 Blocage de la succion à l extrémité du boyau 2 Obstruction dans la tuyauterie du système 3 Utilisation d un accessoire à débit d air restreint par exemple un outil de coin 4 ...

Page 20: ...our les modèles à ACL l écran clignotera jusqu à ce que le problème cesse Si le problème persiste communiquez avec votre détaillant ou distributeur autorisé L unité motrice a besoin d un temps de refroidissement de 30 minutes avant d être redémarrée Voir à la page 23 Image 9 DIAGNOSTICS ET MAINTENANCE Une réduction du débit d air ou de la succion indique que le système central d aspiration ne fonc...

Page 21: ...e détaillant ou distributeur le plus près UNITÉ MOTRICE QUI NE DÉMARRE PAS Vérifiez s il y a un fusible sauté ou un disjoncteur déclenché dans la boîte d alimentation principale de la maison Débranchez l unité motrice et vérifiez tous les branchements des prises d admission et toutes les connexions à basse tension pour vous assurer que tous les fils sont bien fixés Si l unité motrice ne démarre toujou...

Page 22: ...olux Central Vacuum Systems ne sera pas responsable d un tel service à moins qu il n ait été fourni par un détaillant autorisé Electrolux utilisant des pièces de rechange Electrolux Cette garantie ne s applique pas aux pertes ou dommages résultant selon la seule opinion d Electrolux Central Vacuum System d une usure normale d un usage commercial d une négligence d un abus de cas fortuits d acciden...

Page 23: ...380 mm 100 mm Min 70 cm Maximum 1 8 m à partir de la prise Min 30 cm Min 30 cm Min 30 cm Max 5 m Ecran LCD Boutons DEL Réinitialisation Marche arrêt Statut du moteur Vidage du réceptacle à poussière 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 24: ...desean Esto significa que somos muy cuidadosos a la hora de innovar No diseñamos por el hecho de diseñar sino en beneficio del usuario Para nosotros el diseño inteligente consiste en fabricar electrodomésticos más fáciles de usar y en hacer que los quehaceres sean más llevaderos de esta manera los clientes experimentan el más preciado lujo del siglo XXI la tranquilidad Nuestro objetivo es llevar est...

Reviews: