30
Installation manual
14 Waters connections
Washer extractors are assembled in standard execution with only one water inlet.
The supply pipes to the machine should be fitted with manual shut-off valves to facilitate installation and service. Fit
filters to the manual shut-off valves with Teflon. Refer to local utilities regulations when fitting nonreturn valves. A
screen at the entrance to the machine filter should be necessarily mounted, it must have a mesh size of 0.3 mm
Any malfunction of water solenoid or water pneumatic valves due to a absence or a poor maintenance of the filters
will not be taken under warranty.
The following values apply to water pressure:
Water supply pressure, 50 kPa (7.25 psi) mini.
Water supply pressure, 300 kPa (43.5 psi) maxi.
The hoses should be flushed through before being connected to the machine.