43
Installation
Table of pressure and adjustment WD4130
This gas appliance has been build to run on natural gas group I2H and I2E,
commonly identified by GNH. (Japan: LPG).
The data label shows the nozzle size and the nozzle pressure and the
countries that use this gas quality: AT,BG,CZ,DK,EE,FI,GR,HR,HU,IS,IE,IT,
LV, LT,NO,PT,RO,SK,SI,ES,SE,CH,TR,GB,and non-European countries.
Before connecting the appliance please make sure that the supplied gas
type is correct.
Following gas conversions are possible:
•
Appliances to be installed to run on GNH or GNL in FR, BE: I2E+
•
Appliances to be installed in NL, parts of DE: I2L, l2LL.
•
Appliances to be installed to run on LPG in:
BE,CH,CY,CZ,ES,FR,GB,GR,IE,IT, LT,LU,LV,PT,SK,SI : l3+
•
Appliances to be installed to run on LPG in: BE,CY,DK,EE,FR,GB,HU,IT,
LT,NL,NO,SE,SI,SK,RO, HR,TR,BG,IS,LU,MT and Non-European
countries: I3B/P (30 mbar) inlet pressure.
•
Appliances to be installed to run on LPG in: PL: I3B/P (50 mbar) inlet
pressure.
•
Appliances to be installed to run on LPG in: AT,CH,DE,SK: I3B/P
(37 mbar) inlet pressure.
•
Appliances to be installed to run on LPG in: FI,NL,RO and Non-Europe
an countries: I3P (30 mbar) inlet pressure.
•
Appliances to be installed to run on LPG in:
BE,CH,CZ,IE,IT,ES,FR,GR,GB,HR, LT,NL,: I3P (37 mbar) inlet pressure.
•
Appliances to be installed to run on LPG in: AT,CH,DE,NL,LU,SK: I3P
(50 mbar) inlet pressure.
Gas group
Nozzle size
ø mm (1)
Air reducing
plate
Inlet pres-
sure (mbar)
Nozzle
pressure
(mbar)
Label no.
I2H, I2E
3.00
NO
20-25
8
DEFAULT
I2E+
2.30
NO
20/25
20/25
490375601
I2L, 12LL
3.00
NO
20-25
12
490375602
I3+
1.60
2 x F
28-30/37
28-30/37
490375603
I3B/P
1.60
2 x F
30, 37, 50
28
490375604
I3P
1.70
E
30, 37, 50
28
490375605
LPG Japan
1.60
2 x F
28
28
DEFAULT
WD4130 10 kW