![Electrolux W5105N Installation Manual Download Page 34](http://html.mh-extra.com/html/electrolux/w5105n/w5105n_installation-manual_2385463034.webp)
34
Electrical connection
W5130N
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended
fuse
A
200V 3 ~
50/60
5.2
5.7
20
200V 3 ~
50/60
6.9
7.4
25
220–240V 1 ~
50/60
2.5–3.0
3.0–3.5
20
220–240V 1 ~
50/60
4.4–5.2
4.8–5.7
35
220–240V 1 ~
50/60
6.3–7.5
6.8–8.0
35
220–240V 1 ~
50/60
8.4–10.0
8.8–10.4
50
220–240V 3 ~
50/60
2.5–3.0
3.0–3.5
16
220–240V 3 ~
50/60
4.4–5.2
4.8–5.7
20
220–240V 3 ~
50/60
6.3–7.5
6.8–8.0
25
220–240V 3 ~
50/60
8.4–10.0
8.8–10.4
35
380–415V 3 ~
50/60
2.5–3.0
3.0–3.4
10
380–415V 3 ~
50/60
4.4–5.2
4.8–5.7
16
380–415V 3 ~
50/60
6.3–7.5
6.7–7.9
16
380–415V 3 ~
50/60
8.3–10.0
8.8–10.4
20
440/480V 3 ~
60
7.5
8.0
16
440/480V 3 ~
60
10.0
10.4
20
415V 3 ~ /
240V 1 ~
50/60
7.5 /
5.0
7.9 /
5.4
16 /
25
Electric heated
415V 3 ~ /
240V 1 ~
50/60
10.0 /
6.7
10.4 /
6.9
20 /
35
Non heated/Steam heated
200V 3 ~
50/60
-
0.8
10
W5180N
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended
fuse
A
200V 3 ~
50/60
9.0
9.5
35
220–240V 1 ~
50/60
10.9–13.0
11.4–13.5
63
220–240V 3 ~
50/60
10.9–13.0
11.4–13.5
35
380–415V 3 ~
50/60
4.0–4.8
4.5–5.3
16
380–415V 3 ~
50/60
10.9–12.9
11.4–13.4
25
Electric heated
440/480V 3 ~
60
13.0
13.5
25
Non heated/Steam heated
200V 3 ~
50/60
-
1.0
10
Summary of Contents for W5105N
Page 2: ......