18
Installation
Electric installation
The dryer must be given a fuse group of its own
and switch in accordance with IEC 60947.
For each dryer, a multi-pole permanent switch is
to be placed in the permanent installation. It must
be easily accessible, but there must be no mista-
king it for the operating switch for the dryer.
The motor features an integrated thermal fuse,
which is why motor protection in the installation is
unnecessary.
Removethetopplateofthedryertoconnectthe
cable. Install the dryer as a permanent installa-
tion.
See dimensions in the table.
Function check, see next page.
The dryer must be equipped with supplementary
protection in accordance with current regulations.
External fan
A connection terminal is available for controlling
an external fan.
W00199
5
To be carried out by qualified personnel
Connection
of external
contactor
Ext. connection
Max. 1,25A
(Does not apply to marine models)