Electrolux T4130 Installation Manual Download Page 18

18

Installation

Electric installation

The dryer must be given a fuse group of its own 

and switch in accordance with IEC 60947.
For each dryer, a multi-pole permanent switch is 

to be placed in the permanent installation. It must 

be easily accessible, but there must be no mista-

king it for the operating switch for the dryer.
The motor features an integrated thermal fuse, 

which is why motor protection in the installation is 

unnecessary.

Remove­the­top­plate­of­the­dryer­to­connect­the­

cable. Install the dryer as a permanent installa-

tion. 
See dimensions in the table.
Function check, see next page.
The dryer must be equipped with supplementary 

protection in accordance with current regulations.

External fan

A connection terminal is available for controlling 

an external fan.

W00199

5

To be carried out by qualified personnel

Connection

of external

contactor

Ext. connection

Max. 1,25A

(Does not apply to marine models)

Summary of Contents for T4130

Page 1: ...487 05 41 61 EN 2011 09 16 Installation manual Tumble dryers T4130 Type N1130 Compass Control Installation manual in original language ...

Page 2: ......

Page 3: ...g column 12 Condensate dryer 13 Installation of ventilating system 13 Changing over condensate dryers 14 Evacuation system 15 Air principle 15 Fresh air 15 Exhaust duct 16 Electric installation 18 External fan 18 Cable dimensioning table 19 Function check 21 The manufacturer reserves the right to make changes to design and com ponent specifications ...

Page 4: ......

Page 5: ...he machine as soon as they are dried This prevents them from becoming creased and reduces the risk of spontaneous ignition If the machine develops a fault this must be reported to the person in charge as soon as possible This is important both for your safety and that of others The machine must not be located where a door sliding door etc can block the machine s door The machine is not intended to...

Page 6: ......

Page 7: ...to drain 60 70 70 Drum volume litres Weight net kg Drum diameter mm depth mm revolutions rpm g factor Capacity max kg Heat effect kW Motor effect kW revolutions 50 Hz rpm revolutions 60 Hz rpm Air consumption m3 h Piping evacuation ø condensate water Pressure drop evacuation 50 60 Hz max Pa Sound pressure level dB A Technical data T4130 T4130C ...

Page 8: ... Technical data Dimension sketch 100 Ø 100 850 595 735 197 402 500 510 44 49 1260 105 310 550 115 235 78 78 fl 14 Connecting branch condensate dryers only Exhaust duct standard dryers only W00201 W00202 ...

Page 9: ...yer there should be free access to the back of it The dryer can be positioned on a 55 litre wash ing machine to form a washing column Mechanical installation Adjust the dryer to ensure that it is horizontal and stands firmly on all 4 feet The max height adjustment is 14 mm Floor mounting The dryer can be installed directly on the floor and fastened by means of the accompanying cups A Fasten the cu...

Page 10: ...d TOP Upper pivot TOP Lower pivot A 3 Unscrew the cover screws at the opposite side and loosely mount the hinge mounting Screw in the cover screws where the hinge was previously mounted Door reversal 7 Mount the handle at the opposite side where the plugs used to be 8 Insert the plugs where the handle used to be 9 Remove the bottom pivot to the other side 10 Release the locking plates by loosening...

Page 11: ...on board a ship If the dryer is intended for installation on board a ship fittings are mounted from factory instead of feet on the dryer for attachment to the ship floor by means of 4 M8 bolts Drilling plan see fig 1 573 416 100 28 175 12 5 12 5 M8 FRONT ...

Page 12: ...r Screw the dryer feet of the upper machine all the way home to ensure that they do not touch the top plate of the lower machine Lift the dryer into position thereby making sure that the machine fronts are flush As a protection against tilting the two ac companying plate screws are to be inserted in either side in holes B If holes B are not provided in the side plates drill them with a 3 3 mm dril...

Page 13: ...water in the drains Note The hose must be sloping towards the drain and not form a water trap Installation of ventilating system For ventilation a thermostatically controlled fan type EQ 250 is used It can be ordered as item no 988 80 20 43 The fan is to be placed on a wall facing the outside behind the condensate dryer while the thermostat is placed further into the room in an accessible place Th...

Page 14: ...allation Changing over condensate dryers To be carried out by qualified personnel 3 x 400 415V N 3 4kW B1 3 x 200 230 240V 3 4kW B1 1 x 230 240V 3 4kW B1 Applies to all dryer types W00193 W00194 W00195 W00196 ...

Page 15: ...shor test possible drying time it is important for the air input to the room to come from an aperture from outside through which the same amount of air is taken into the room as is blown out To avoid a draught in the room the air inlet should prefera bly be placed behind the dryer The free area of the air inlet aperture must be five times the area of the exhaust duct The re sistance in the grating...

Page 16: ...s or other fuels as their energy source When several dryers share an exhaust duct The exhaust duct diameter must increase after each dryer The table below shows the exhaust duct diameter and the necessary fresh air inlet area Note It is recommended that each dryer is connected to a separate exhaust duct The evacuation pipe diameter must not be reduced No of dryers 1 2 3 4 Exhaust m3 h 260 520 780 ...

Page 17: ...17 Installation 9 W00198 W00145 8 Several dryers share an exhaust duct Gentle bends ...

Page 18: ... thermal fuse which is why motor protection in the installation is unnecessary Remove the top plate of the dryer to connect the cable Install the dryer as a permanent installa tion See dimensions in the table Function check see next page The dryer must be equipped with supplementary protection in accordance with current regulations External fan A connection terminal is available for controlling an...

Page 19: ... A Standard dryer 400 440V 3N 3 AC 5 3 5 1 10 200 240V 3 AC 5 3 5 1 16 230 240V 3 AC 3 4 3 2 10 230 240V 1 AC 3 4 3 2 16 Condensate dryer 400 440V 3N 3 AC 3 4 3 0 10 230 240V 3 AC 3 4 3 0 10 230 240V 1 AC 3 4 3 0 16 200V 3 AC 3 4 3 0 16 Cable dimensioning table ...

Page 20: ......

Page 21: ...3 phase motor the direction of rotation must be checked If the direction of rotation is not correct swop two phases on the connection terminal Final test Let the dryer work for 5 minutes on a program that requires heat Then check whether the heating is working by opening the front door and feel the heat If the above tests points are in order the dryer is ready for use Service organisation dealer I...

Page 22: ......

Page 23: ......

Page 24: ...Electrolux Laundry Systems Sweden AB 341 80 Ljungby Sweden www electrolux com laundrysystems Share more of our thinking at www electrolux com ...

Reviews: