Programming

Adjusting operating temperatures

1.­ Press­Enter. 

The display shows 0 01, indicating Group 0, parameter 

location­01­=­High­temperature.

2.­ Press­Enter­again­to­enter­this­parameter­location.­The­

display­shows­_­70­(°C).

  Note: The flashing bar at the bottom of the left digit 

indicates that this is a two-digit parameter. 

3.­ Press­Enter­key­to­edit­this­parameter­value.­The­“70”­will­

begin­to­flash.

4.­ Press­Down­to­lower­the­value­or­Up­to­increase­it.
 

Note: The Up and Down may be pressed and held to 

make more rapid value changes.

5.­ Press­Enter­key­to­save­the­new­value
­ In­this­example,­the­High­temperature­has­been­changed­

to­65°C.­The­value­is­saved­when­the­parameter­stops­

flashing and the flashing _ reappears­in­the­left­digit.

6.­ Press­Return­to­leave­this­parameter.
7.­ To­adjust­the­Medium­or­Low­temperature,­press­Up­to­go­

to­the­proper­parameter­location.

  Location 0 02 is the Medium drying temperature (factory 

set­to­60°C). 

Location 0 03 is the Low drying temperature (factory set 

to­50°C).­ 

Press­Down­to­go­back­if­you­pass­the­desired­location.­

  Press Enter to enter and edit the Medium or Low tempe-

rature,­as­described­in­steps­3-5.

8.­ Press­service­button­A­when­the­programming­is­done.
9.­ Assemble­and­test­the­dryer.

487 22 93 40.00

SELECTA CONTROL

487 09 10 00.00

487 22 93 40.00

SELECTA CONTROL

487 09 10 00.00

487 22 93 40.00

SELECTA CONTROL

487 09 10 00.00

487 22 93 40.00

SELECTA CONTROL

487 09 10 00.00

487 22 93 40.00

SELECTA CONTROL

487 09 10 00.00

1.

487 22 93 40.00

SELECTA CONTROL

487 09 10 00.00

2.

3.

5.

4.

6.

487 22 93 40.00

SELECTA CONTROL

7.

Summary of Contents for T41200

Page 1: ... Selecta II Control T4290 T4530 T4650 T4900 T41200 T4300S T4420S TD30 TD50 TD75 TD100 TD135 TD30x30 TD45x45 WD4130 WD4240 T4250 from machine no 23350 0006970 T4350 from machine no 23250 0003715 487 05 40 01 EN 2011 01 11 ...

Page 2: ......

Page 3: ...to design and com ponent specifications Contents Safety precautions 5 Programming 7 Gas reset button 7 Operating panel 8 Quick diagram 9 Changing of parameters in Group 0 10 Reading the hour counter in Group 1 12 Parameter overview Area A 13 Error codes overview 14 ...

Page 4: ......

Page 5: ...he machine as soon as they are dried This prevents them from becoming creased and reduces the risk of spontaneous ignition If the machine develops a fault this must be reported to the person in charge as soon as possible This is important both for your safety and that of others The machine must not be located where a door sliding door etc can block the machine s door The machine is not intended to...

Page 6: ......

Page 7: ...m the dryer see Service Manual for Selecta Control from ver 4 xx for programming details Gas reset button The button B is the gas reset button High voltage on the printed circuit board Note that there is high voltage on the circuit board Never touch high voltage parts without first breaking the current at the main power switch 1 A B 1 1 High voltage ...

Page 8: ... when the dryer is in service mode In service mode the 4 buttons are used for changing the parameters Selected temperature Light emitting diode is lit at the selected temperature or show the default temperature setting Default temperature can be set in Group B in parameter A 05 2 487 09 10 01 00 SELECTA CONTROL Down Up Enter Return High No heat Medium Low Programming ...

Page 9: ...Total coins inserted coin 1 1 05 Total coins inserted coin 2 Note If a mistake is made or confusion arises while programming the dryer press the service button and start again During the programming process Enter is used to save new settings If you leave programming mode before pressing Enter to save a new setting the original value will be retained Group 1 Reading total counters 1 01 1 05 Group 2...

Page 10: ...coin or push value The value in this location is the number of drying minutes that will be added when a coin is deposi ted coin machines or Up is pushed 3 Press Enter to enter this location and view its contents Note The flashing bar at the bottom of the left digit indicates that this is a two digit parameter 0 to 99 minutes 4 Press Enter again to select this value for editing The cur rent value 1...

Page 11: ...lashing and the flashing _ reappears in the left digit 6 Press Return to leave this parameter 7 To adjust the Medium or Low temperature press Up to go to the proper parameter location Location 0 02 is the Medium drying temperature factory set to 60 C Location 0 03 is the Low drying temperature factory set to 50 C Press Down to go back if you pass the desired location Press Enter to enter and edit ...

Page 12: ...es that these are the two middle digits of the six digit hour counter 00 02 xx hours 5 Press Down again The display now shows 08 The flashing bar at the bot tom of the left digit now indicates that these are the last two digits of the six digit hour counter 00 02 08 hours In this example the total hour counter shows that the dryer has operated for 208 hours 6 Press service button A when the progra...

Page 13: ...er coin 2 1 90 mins 1 min 30 Time interval 0 08 Min time before start 0 90 mins 1 min 0 Only on dryers with payment 1 01 Hour counter 0 999999 hrs 0 Permanent total hour counter 1 02 Hour counter 0 999999 hrs 0 Resettable trip hour counter 1 03 Service hour counter 0 999999 hrs 0 Hours before next service 1 04 Coin counter 1 0 999999 coins 0 Total no of coins inserted coin type1 1 05 Coin counter ...

Page 14: ...E 10 Incorrect programming One or more parameters are incorrect or is missing E 11 Drying error with RMC program The longest permitted RMC time has been exceeded Applies only to machines with RMC E 12 Drying error with autostop program The longest permitted automatic stop time has been exceeded Applies only to machines with automatic stop E 13 Drying error with time program The set drying time is ...

Page 15: ... error no polling CBT The computer has not called the tumble dryer during the timeout period E 23 Not in use E 24 Condensate container is full The condensate container is full and the pump is not operating E 25 Damper output air is not closed correct Applies only to Clean Room tumble dryers E 26 Damper output air is not open correct Applies only to Clean Room tumble dryers E 27 Hepa filter pressur...

Page 16: ...Electrolux Laundry Systems Sweden AB 341 80 Ljungby Sweden www electrolux com laundrysystems Share more of our thinking at www electrolux com ...