IGNITER SPARK GAP 

The distance between the tip of the igniter and the top edge of the 
burner head gauze should be a minimum of 3mm. 

HEATERS FOR ELECTRIC OPERATION

For electric operation, the boiler of the cooling unit is fitted with
two separate heaters. The one near the back of the refrigerator casing 
has black leads and is for use on 12V. The other has brown leads, and 
an earth connection tag, and is for use on 220 to 240V. The 12V 
heater is rated at 95 watts, and the mains voltage heater, 100 watts. 

SERVICE 

Should you require help or service in connection with your refriger 
ator, please refer to addresses on back pages. 

 

 

 

 

4 .   R e m o v e   s c r e w   h o l d i n g   b u r n e r   b r a c k e t   ( 1 1 )   t o   b o i l e r ,   r e l e a s e

5 .  

bracket tongues from slot in boiler, then carefully move burner 
bracket assembly to one side, clear of the flue tube. 
Clean burner and adjacent components of soot etc. without dis 

6. 

turbing their relative positions. 
Clean flue tube of boiler - a special flue brush (part No. 151404) 

7 .  

is available as an extra for this purpose. 
Reassemble equipment, engaging tongues in top of burner bracket 

8. 

(11) in corresponding slot in bottom of boiler before replacing 
fixing screw. Gas unions must be tight but not overtightened. 
Operate button (4) of igniter whilst watching to check that spark 

9 .  

jumps from electrode to burner head. (See next section). 
Referring to item 'Checking for Gas Leaks', re-install refrigerator, 

 

light burner and leave on test to ensure that it operates properly. 

 

 