background image

Please read instructions carefully. Service calls resulting from incorrect installation will be charged for. 

Exhaust air from the cooker hood must not be discharged into any heating flue which may carry
combustion products from other sources. In addition, exhaust air must not be discharged into a wall 
cavity, unless the cavity is designed for the purpose. Adequate ventilation of the room must 
be ensured when the cooker hood is operating simultaneously with appliances burning gas or 
other fuels. Installation must comply in all respects with your gas and electrical authorities. This 
cooker hood is an indoor domestic appliance, and has been manufactured and tested to comply 
with Australian and New Zealand Standard

 

AS/NZS 60335.2.31

It is recommended th

FIXING POINT DIMENSIONS - 600mm Retractable cooker hood

FIXING POINT DIMENSIONS - 900mm Retractable 

cooker hood

INSTALLATION INSTRUCTIONS

600

650

GAS

ELECTRIC

Ducting hole
cover

Duct Spigot

DUCTING INSTALLATION

When installing with ducting pipe the Duct 
spigot must be fitted to the ducting hole 
on top of the body of the cooker hood

RECIRCULATING INSTALLATION

(For Models: WRH608I*  WRR614*A & WRH908I*) 

When installed in recirculating mode the 
ducting hole cover must  be fitted

P2

13427_Rangehood_Electrolux.indd   3

OPERATION GUIDE & INSTALLATION INSTRUCTIONS

The maximum space between the wall and screw cap is 5mm.

Warning: Failure to install the screws or fixing device in accordance with these instructions may result in 
               electrical hazards.

at the unit be positioned at a mininum of 600mm from an electric cooktop

and 650mm for a gas cooktop, and no further from the cooktop than 800mm. Then unit 
becomes less effective as the distance from the cooking surface to the hood increase.

Summary of Contents for REHR6 Series

Page 1: ...ATION INSTRUCTIONS Model REHR6 WRH605I WRH608I WRR614 A WRH908I These cooker hoods are domestic appliances which have been manufactured and tested to comply with Australian and New Zealand Standard AS NZS 60335 2 31 13427_Rangehood_Electrolux indd 1 ...

Page 2: ...urners before you remove pots or pans Cleaning Wipe the cooker hood body and flue with a sponge or soft cloth soaked in warm soapy water and dry with a soft cloth for stainless steel models apply a stainless steel protector Do not use oven cleaners or other abrasive materials Electrical Connection Check that the mains voltage matches with the voltage on the data plate inside the cooker hood Check ...

Page 3: ...POINT DIMENSIONS 600mm Retractable cooker hood FIXING POINT DIMENSIONS 900mm Retractable cooker hood INSTALLATION INSTRUCTIONS 600 650 GAS ELECTRIC Ducting hole cover Duct Spigot DUCTING INSTALLATION When installing with ducting pipe the Duct spigot must be fitted to the ducting hole on top of the body of the cooker hood RECIRCULATING INSTALLATION For Models WRH608I WRR614 A WRH908I When installed...

Page 4: ... be bought through your local appliance retailer or in Australia online at shop electrolux com au RETRACTABLE COOKER HOOD P3 PARTS SUPPLIED WITH HOOD 1 Duct Spigot 1 Ducting hole cover only for WRH608I WRR614 A and WRH908I 4 M6 40 screws 4 φ6 washers 2 Carbon filters only for WRR614 A PARTS TO BE PURCHASED Aluminium tape or cable ties to secure flue pipe Custom drawer fascia if required Ducting ac...

Page 5: ...upport from upper side STANDARD DUCTED INSTALLATION RETRACTABLE COOKER HOOD P3 2 Fixing duct spigot 1 Drilling holes 3 Fixing the cooker hood 4 Fixing flue pipe to φ7 for hood fastening screws Door hood fascia Front of cabinet 36 drill φ7 hole drill φ45 hole cut φ130 hole 210 470 770 φ clearance hood the duct spigot 200 100 268 φ45 for Cable clearance pulled taut to minimise pressure loss and nois...

Page 6: ...e cooker hood is to be vented using the recirculating vent rather than standard ducting the supplied drawer fascia is not to be used and must be replaced with a client specific custom fascia The custom drawer fascia must be a minimum of 70mm deep as air expelled through the recirculating vent must be deflected upwards INSTALLATION INSTRUCTIONS 130 40 3 101 70 3 RECIRCULATE EXHAUST Setting of circu...

Page 7: ...S REHR6 WRH605I WRH608I WRR614 A WRH908I ALL MODELS OPTIONAL CARBON FILTER An optional carbon filter will diminish cooking odours in the recirculated air Depending on the frequency of use and the type of cooking the expected life of carbon filters is from 1 to 6 months Replacement is required Recirculating accessory ARCFD ...

Page 8: ...y the drawer action see diagram OPERATION MAINTENANCE MAINS SWITCH OFF TO REPLACE LIGHT GLOBES 1 Open drawer and remove filter 2 Turn mains switch off before removing lamp Replace with 28W maximum E14 candle lamp Depending on model will require 1 or 2 globes The lamp assembly includes a silicone seal this must be replaced when a new lamp is used The silicone seal is placed over the lamp thread and...

Page 9: ...h before cleaning drawer and cooker hood body 5 After cleaning re fit filters making sure the clip pins are securely fitted into the locating holes in the cookerhood body and for twin filter versions also located in the pull out drawer section 6 Holding clip in push opposite side of filter up until pins are over locating holes 7 Release clip ensuring filter is securely fitted Safety Tips Use of tw...

Page 10: ...misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii failure to comply with any additional instructions supplied with the Appliance b c the Appliance s serial number or wa...

Page 11: ...NOTES 13427_Rangehood_Electrolux indd 10 ...

Page 12: ...www electrolux com au www electrolux com nz PLEASE LEAVE THIS BOOKLET WITH THE COOKER HOOD OWNER THANK YOU Version 00 02 Nov 2015 ...

Reviews: