9. TECHNICAL DATA
9.1 Hob dimensions
Width
595 mm
Depth
510 mm
9.2 Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Multi Crown
57
Semi-rapid
35
Auxiliary
28
9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar
8,7 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar
621 g/h
G31 (3+) 37 mbar
611 g/h
Electric sup‐
ply:
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car‐
tridge fuse
Appliance cat‐
egory:
II2H3+
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Multi Crown
4,0
1,4
146
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
www.electrolux.com
18