# Measure the resistance windings of the compressor.
The resistance value will range between 0.45 to 0.88 ohms at an ambient temperature range of 20 to
25ºC.
Note:
the resistance value should be the same value
across any terminal combination.
#
Check the LED light code configuration.
During normal operating conditions the LED’s work in this sequence:
LED 1 (Yellow) is
ON
LED 5 (Red) is
ON
LED 6 (Green) is
OFF
During “P4” fault the LED’s work in this sequence:
LED 1 (Yellow) is
FLASHING
at 5 Hz
LED 5 (Red) is
ON
LED 6 (Green) is
FLASHING
at 5 Hz
Note:
If the LED’s are “NOT” On or Flashing, check the supply voltage to the board. If supply voltage
is okay, this would indicate the main outdoor PCB has failed.
Page 29 KSSSI90