background image

Page 2  KSSSI92 

 

 

 

Indoor Unit & PCB test board Error Display

 

DISPLAY 

LED STATUS 

PAGE 

Not 

Operating 

No operation by use of remote control. 

E0 

EEPROM parameter error. (Indoor Unit) 

F0 

Over current error 

F4 

EEPROM parameter error. (Outdoor Unit) 

E1 

Indoor / outdoor units communication protection. 

6 to 14 

F1, F2 & F3 

Open or short circuit of outdoor condenser pipe, outdoor ambient temperature & compressor 

temperature sensors. 

15 & 16 

E4 & E5 

Open or short circuit of room or evaporator temperature sensors. 

17 

F5, L2 & PA 

High & Low-temperature protection of condenser / Outdoor fan motor feedback circuit error.  18 & 19 

P0 

Module protection. 

20 

P2 

Temperature protection of compressor top - low refrigerant charge. 

219 

P4 

Inverter compressor drive error. 

22 & 23 

P1 

Over voltage or too low voltage protection. 

23 

E3 

Indoor fan motor circuit error. 

24 