- 20 -
DGN-TDS-N 11.03 U. H. / A. B. © Electrolux
599 512 232
EN
E 2
E
E
0
0
4.11 Alarm messages
It is possible that an alarm message involves the whole hob or that only 1 zone is not functional.
This message includes the number and the zones for which the message is valid.
Procedure – Failure occurs during cooking
For 10 sec. Beep 1 Hz (like continuously pressed button) and display of the error number plus op-
tional the number of the power board with failure.
After 10 sec or after a press on one button (all buttons) the user interface toggles to the next status,
there the zones without alarm can be used normal. On the zones with alarm an „E“ is shown.
If the hob is switched on with the main switch and an alarm is still active the alarm is shown for 10
sec. as above (incl. Beep and press main button again). The UI stores the alarm of each module
and shows the alarms in succession if several alarms are active. The hob is in “normal” standby
modus and the cooking levels and timers are set to 0.
The following error codes are shown:
Alarm number
For the induction (HC2) means this that besides the error code 7 for the temperature sensor all
zones connected to this module are blocked / switched OFF.
Error-Code
Display
Name Comments
E-0
Config_Data_ALM_HC
Wrong Configuration on HC /
EEPROM checksum failure
E-1 TEMP_CoolBlock_ALM_L
E-2
TEMP_CoolBlock_ALM_R
E-3
Phase1missing_L
Phase not detected on powerboard
induction Left
E-4
Phase2missing_R
E-5 CommErrorPowerBoard_L
Internal Ind.Bus error/ missing
connection / 12VDC or 5VDC missing
E-6
CommErrorPowerBoard_R
E-7
Temperature probe coil
Error of min. 1 cooking zone
(see alarm codes message def.)
E-8
Communication error to power
board
E-9
(E-3)
Config_Data_ALM_HUI
HUI received invalid configuration