background image

www.electrolux.com

6

Power off

 

Power down the product by gently touching the 

ON/OFF icon on the center of the product.

Child lock

 

To enable CHILD LOCK by long pressing ON/OFF 

icon for 5 seconds, and numerical display shows 

LOC for 3 seconds. After 3 seconds the LOC text 

dissapear and IAQ appears. LOC text reappear 

when during child lock any of the controls are 

touched. When in this mode, no other icon will 

register input (ref. picture 7).

12

13

UV-C emitter control

 

Activate the UV feature by gently touching UV 

icon on the product, and the UV-C emitter will 

light on. The UV-C emitter can help eliminate 

bacteria in the product. (ref. picture 11).
Touch the button again to turn off the UV feature.

11

Sleep mode

 

Chose the SLEEP mode by gently touching " "  

icon on the product. In SLEEP mode unit will 

operate at the low noise level and all indicators 

except for SLEEP icon will go off. (ref. picture 10).

Air speed control

 

Change the fan speed by gently touching desired 

fan speed icon on the product. You can also slide 

your finger across the arc to change fan speed  

(ref. picture 8).

Auto mode

 

Chose the AUTO mode by gently touching "A" icon 

on the product. In AUTO mode the unit will adjust 

operation according to latest air quality (PM2.5 

level).  (ref. picture 9).

10

8

9

AIR QUALITY INDICATOR

The appliance has an air quality sensor that 

analyzes the air quality.
The air quality light will show the real-time air 

quality through different colors of light. As shown 

below:

14

LIGHT'S COLOR

Blue

Green

Orange

Red

PM 2.5 (μg/m

3

)

AIR QUALITY

0-15

Very Good

16-35

Good

36-75

Bad

>75

Very Bad

FILTER CHANGE INDICATOR

The filter change indicator will light up to 

remind you to change the filter.

• When filter change indicator flicker with red 

light, please replace the filter and reset the filter 

change indicator.
• When filter change indicator stop flicker and the 

red light fix, please replace the filter immediately 

and reset the filter change indicator. 

15

16

Filter change indicator reset operation

 

Press the filter change button " "for 3s and filter 

change indicator will reset, then red light will go off.

UV-C EMITTER REPLACEMENT

The UV indicator will blink to remind you to 

change the UV-C emitter. 

Please replace the UV-C emitter as following 

steps (ref. picture 12) and reset the UV change 

indicator.
Caution: The appliance must be disconnected 

from the supply before replacing the UV-C 

emitter.

1&2. Open the product by rotating the base 

in anticlockwise direction with the handle 

provided at the bottom.

3. Remove the filter from the unit.
4. Grasping the UV-C emitter with a clean cloth 

or a tissure and pulling straight out of the unit 

carefully.

17

Caution: After filter is installed correctly, please 

ensure product is placed on a level surface 

before proceeding further. Ensure there is 

enough free space on top of and around the 

product.

OPERATION

Connect the power plug.
Power on

 

Power on the product by gently touching the 

ON/OFF icon on the center of the product 

(ref. picture 7).

6
7

Install the filter

 

Carefully insert the filter back into the product 

without the plastic packaging (either end of the 

filter works). Take care that the filter is placed in 

the center of the cavity (ref. picture 4).

Close the base

 

Close the product by rotating the base in 

clockwise direction with the handle provided at 

the bottom till it is securely in place. There two 

opposing triangular marks on the base of the 

product to identify the leading edge for turning 

(ref. picture 5).

4

5

To disable CHILD LOCK, long press ON/OFF icon 

again for 5 seconds till the LOC text dessapear 

and IAQ appears.

Install the UV-C emitter.

 

Grasping the UV-C emitter with a clean cloth or a 

tissure and inserting it in carefully. (ref. picture 3).

3

packaging from the unit and break open the 

plastic bag and discard appropriately. 

(ref. picture 2).

Summary of Contents for FA41-403BL

Page 1: ...FA41 403WT FA41 403PK FA41 403GN FA41 403BL FLOW A4 Instruction Book Models A4UV01_210511 ...

Page 2: ... O Filter inside P UV C emitter inside Control panel G Air quality digital display H Fan speed control I Power on off J Air quality color indicator K Sleep mode button indicator L Auto mode button indicator M Filter change reminder N UV button indicator UV C kill bacteria on over filter 3 hours DESCRIPTION OF YOUR AIR PURIFIER FLOW A4 ...

Page 3: ...www electrolux com 3 1 5 8 11 2 3 6 9 4 7 10 12 3 4 5 6 ...

Page 4: ...abels for flammability and other warnings Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and or a fire hazard Do not touch the fan blade when removing the filter Children and Vulnerable People Safety WARNING Risk of suffocation injury or permanent disability This appliance is not intended for use by persons including children with reduced ph...

Page 5: ...age to the unit or other property Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups Do not climb on or place objects on the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the unit at the power source when it will not be used for an extended period of time Operate the unit with air filter in place Do not ...

Page 6: ...When filter change indicator stop flicker and the red light fix please replace the filter immediately and reset the filter change indicator 15 16 Filter change indicator reset operation Press the filter change button for 3s and filter change indicator will reset then red light will go off UV C EMITTER REPLACEMENT The UV indicator will blink to remind you to change the UV C emitter Please replace t...

Page 7: ... CODE If you are not planning to use the appliance for a long time cover it with plastic or return it to its carton Fan failure error code when digital display area shows E01 it means the fan failure occurs Motor will stop working PM sensor failure error code when digital display area shows E02 after unit runing 10min later unit will keep running it means the PM sensor failure occurs 22 23 24 NOTE...

Page 8: ......

Page 9: ...www electrolux com 3 1 5 8 11 2 3 6 9 4 7 10 12 3 4 5 6 ...

Page 10: ...ดอ านฉลากผลิตภัณฑ ส ำหรับข อมูลเกี ยวกับการติดไฟและค ำเตือน อื นๆ ระมัดระวังอย าให น ำ หรือของเหลวประเภทอื นๆ หรือน ำยาท ำความสะอาดที ติดไฟได เข าไปในเครื อง เพื อหลีกเลี ยงความเสี ยงในการถูกไฟฟ าช อต และ หรือเกิดเพลิงไหม ห ามสัมผัสใบพัดลมขณะถอดแผ นกรอง ความปลอดภัยของเด กและผู ที มีความเสี ยง ค ำเตือน เสี ยงต อการขาดอากาศหายใจ ได รับบาดเจ บ หรือทุพพลภาพถาวร เครื องใช ไฟฟ านี ไม ได มีไว ส ำหรับใช ง...

Page 11: ...กอุปกรณ ไฟฟ า อิเล คทรอนิกส 30 ซม ใช งานผลิตภัณฑ นี ร วมกับอุปกรณ เสริมที มาจากผู ผลิตและตัวแทน ฝ ายบริการเท านั น ผลิตภัณฑ จะปิดเอง หากผลิตภัณฑ เอียงไปในทิศทางใดๆ และเกิน 30 10 องศา เนื องจากมีสวิตช เปิด ปิดเพื อความปลอดภัย ในตัว หากต องการเริ มการท ำงานใหม เพียงวางผลิตภัณฑ ตั งตรง ข อควรระวังเกี ยวกับหลอด UV C ข อควรระวัง เพื อป องกันไม ให เกิดการบาดเจ บรุนแรง หรือ ถึงขั นเสียชีวิต ผลิตภัณฑ นี ม...

Page 12: ... องการเปิดใช งานฟังก ชั นล อคป องกันเด ก ให กด ไอคอน ON OFF ค างไว 5 วินาที จากนั นจอแสดงผล ตัวเลขจะแสดงข อความ LOC นาน 3 วินาที หลังจาก ผ านไป 3 วินาที ข อความ LOC จะหายไป และ IAQ จะปรากฏ ในระหว างฟังก ชั นล อคป องกันเด กท ำงาน ข อความ IAQ จะปรากฏขึ นอีกครั งเมื อมีการแตะปุ มควบคุม ปุ มใดปุ มหนึ ง ขณะอยู ในโหมดนี ไอคอนอื นๆ จะไม แสดง ดูรูปที 7 หากต องการยกเลิกการใช งานฟังก ชั นล อคป องกันเด ก ให ...

Page 13: ......

Page 14: ......

Reviews: