Technical Support - DMM
89/106
599 77 23-65 Rev. 03
16.3.2 Door safety interlock
Remove the iron ring securing the bellow seal to the unit.
Remove the part of the bellow seal concerned from the unit.
Unfasten the two screws securing the door safety interlock to the front panel.
Take the device and move it to the left.
Turn it towards the inside (right-hand side of the flange).
Pull it out towards the right and remove it.
Pull out the door safety interlock.
Take care in the lower part of the device as there is a small rod.
Don
’t pull it out too much otherwise the small rod comes out of its seat in the
filter body, as described below.