Technical Support - A.D.L. 02 / 2011
16/24
599 74 08-64
5.3
Alarm Summary Table
ALA
R
M
CO
DE
Description
Possible fault
Machine status/action
Reset
E11
Water fill difficulty during washing
Tap
closed.
Water pressure too low.
Drain pipe improperly positioned.
Water fill solenoid valve faulty.
Leaks from pressure switch water circuit.
Pressure switch faulty.
Faulty
wiring.
Main circuit board faulty.
Cycle is paused with door locked
START/RESET
E13
Water leaks
Drain pipe improperly positioned.
Water pressure too low.
Water fill solenoid valve faulty.
Leaks/clogging of pressure switch water circuit.
Pressure switch faulty.
Cycle is paused with door locked
START/RESET
E21
Drain difficulty during washing
Drain tube kinked/clogged/improperly positioned.
Drain filter clogged/dirty.
Faulty
wiring.
Pressure switch faulty.
Drain pump rotor blocked.
Drain pump faulty.
Main circuit board faulty.
Cycle is paused (after 2 attempts)
START
ON/OFF
RESET
E23
Faulty triac for drain pump
Faulty
wiring.
Drain pump faulty.
Main circuit board faulty.
Safety drain cycle - Cycle stops with door open
RESET
E24
Malfunction in sensing circuit on
triac for drain pump
Main circuit board faulty.
Safety drain cycle - Cycle stops with door
unlocked
RESET