Fig. 8
2.1 Kg (6.0kW model) / 2.3 Kg (8.0kW model)
ELCB TESTING
WIRING DIAGRAM - ELECTRICAL CONTROL WITH ELCB
EWE602IX1DWX3
SPECIFICATIONS (TABLE 2)
ELECTRICAL LOADING
WATER CONNECTION
DIMENSIONS
WEIGHT
MIN. WATER FLOW RATE
TYPE
6.0kW, 220V ac (single element) / 8.0kW , 220V ac (double element)
Electronic power control
3 Liter / min.
1/2’’ bsp multipoint system
272 x 196 x 102 (mm)
printing and may be subjected to change without prior notice.
ELCB Test Lever
ELCB Reset Lever
6. TEST RUN
11
ENGLISH
10
www.electrolux.com
7.
MAINTENANCE
8.
WIRING DIAGRAM
9.
ELECTRICAL SPECIFICATION
E
N
L
T2
G
N1
TRIAC
Manual Reset
Thermal
Cut- Out
& Thermostat
Heater
Tank
Power ON/OFF
Temp. Control
Flow
Switch
FS
FS
LED BOARD
T2
N
2P ELCB
30A
15mA,
<0.1s
E
WIRING DIAGRAM - ELECTRICAL CONTROL WITH ELCB
EWE802IX1DWX3
E
N
L
T2
G
N1
TRIAC
Manual Reset
Thermal
Cut- Out
& Thermostat
Heater
Tank A
Power ON/OFF
Temp. Control
Flow
Switch
FS
FS
LED BOARD
T2
N
2P ELCB
40A
15mA,
<0.1s
E
Heater
Tank B
6.1
6.2
6.3
6.4
Turn on the water supply and Stop
Valve, the water will flow through the outlet.
Switch on the power supply. The 2 LED
Indicator light shall run ON/OFF 3 times in
sequences to indicate the set are self checking.
If the Heater Unit is not earthed properly, the
Earth Led indicator light will OFF, during usage
or standby. Earth Led indicator light also
OFF if Live & Neutral reverse connection.
Turn the Temperature Control Knob to
‘ON’, the Red (Power) LED Indicator will light up
, hot water will flow out within a few seconds.
The more Temperature Control Knob is turned
in clockwise direction, the hotter is the water.
The shower bath, long bath, wash basin
might not be hot enough even at the ‘MAX’
position if incoming water supply from the mains
is too cold or the pressure of water is too high. In
this case, you may adjust the incoming cold water
mixer valve to reduce the water inflow in order to
get the desired water temperature.
6.5
Check the Built-in ELCB as follows:
Pull the ELCB TEST LEVER down,
the
Built-in ELCB should trip and cut off the
power supply, Red and Green
LED Indicator should light off.
Pull the ELCB RESET LEVER down to
reset the ELCB,
the 2 LED Indicator light
shall run ON/OFF 3 times in sequences to
indicate self checking and the Heater Unit
should resume normal function, the Green
LED Indicator should light on. If procedures
stated above prevailed, the ELCB is
functioning in normal condition.
.
.
It is unnecessary to turn the Temperature
Control Knob to ‘OFF’ position when the Heater
Unit is not in use.
Explain to the user how the unit works
and familiarise him or her with its use.
Advise the user about possible hazards
(high water temperature)
Hand over these instructions, to be kept in a
safe place.
.
.
6.6
6.7
Read the section ‘SAFETY INFORMATION’ first.
Test the ‘ ELCB’ regularly
7.1
Clean the
fi
lter regularly
7.2 Clean the Mesh Filter regularly to prevent blockage.
When carrying out any work, isolate the unit from the mains
and shut off the water connection.
7.3
Cleaning precaution!
7.4 Do not use thinner, alcohol, petrol or any other
organic solutions to clean the set.
Use only dampeded cloth
with mild detergent.
This procedure is a highly recommended test to be
carried out at least once a month. Turn on the power supply
and water supply, both Red (Power) and Green (ELCB)
indicators will light up if the Temperature Control Knob is in
‘ON’ position.
Pull the ELCB TEST LEVER down, Red (Power) and Green
(ELCB) Indicator should go off.
Pull the ELCB RESET LEVER down
to reset the ELCB
,resume the power supply. (Fig 8)
If the Power Indicator does not go off when you pull
the ELCB Test lever, switch OFF the mains supply and
contact sales agent for repair service. Special skill is required
for repairing. NEVER try to repair the unit by yourself.
WARNING !
MIN. INLET WATER PRESSURE
MAX. INLET WATER PRESSURE
1.0 Bar (100kPa; 14.5 psi)
6.0 Bar (0.6 MPa ; 87.02 psi)
Summary of Contents for EWE602IX1DWX3
Page 8: ...NOTE NOTE ...