background image

Fig. 8

 

    

 

 

 

 

2.1 Kg (6.0kW model) / 2.3 Kg (8.0kW model)

ELCB TESTING 

WIRING DIAGRAM - ELECTRICAL CONTROL WITH ELCB 

EWE602IX1DWX3

SPECIFICATIONS (TABLE 2)

ELECTRICAL LOADING

WATER CONNECTION

DIMENSIONS

WEIGHT

MIN. WATER FLOW RATE

TYPE

6.0kW, 220V ac (single element) / 8.0kW , 220V ac (double element)

Electronic power control
3 Liter / min.

1/2’’ bsp multipoint system
272 x 196 x 102 (mm)

printing and may be subjected to change without prior notice.

ELCB Test Lever

ELCB Reset Lever

6.  TEST RUN

11

ENGLISH

10 

www.electrolux.com

7.

MAINTENANCE

8.

WIRING DIAGRAM

9.

ELECTRICAL SPECIFICATION

E

N

L

T2

G

N1

TRIAC

Manual Reset

Thermal  

Cut- Out

& Thermostat

Heater 

Tank

Power  ON/OFF  

Temp. Control

Flow 

Switch

FS

FS

LED BOARD

T2

N

2P  ELCB

30A

15mA, 

<0.1s

E

WIRING DIAGRAM - ELECTRICAL CONTROL WITH ELCB 

EWE802IX1DWX3

E

N

L

T2

G

N1

TRIAC

Manual Reset

Thermal  

Cut- Out

& Thermostat

Heater 

Tank A

Power  ON/OFF  

Temp. Control

Flow 

Switch

FS

FS

LED BOARD

T2

N

2P  ELCB

40A

15mA, 

<0.1s

E

Heater 

Tank B

6.1 

6.2 

6.3 

6.4 

            Turn on the water supply and Stop 

Valve, the water will flow through the outlet.

           

Switch on the power supply. The 2 LED 

Indicator light shall run ON/OFF 3 times in 

sequences to indicate the set are self checking.

If the Heater Unit is not earthed properly, the 
Earth Led indicator light will OFF, during usage 
or standby. Earth Led indicator light also 
OFF if Live & Neutral reverse connection.

            Turn the Temperature Control Knob to 

‘ON’, the Red (Power) LED Indicator will light up 

, hot water will flow out within a few seconds. 

The more Temperature Control Knob is turned 

in clockwise direction, the hotter is the water. 

             The shower bath, long bath, wash basin 

might not be hot enough even at the ‘MAX’ 

position if incoming water supply from the mains 

is too cold or the pressure of water is too high. In 

this case, you may adjust the incoming cold water 

mixer valve to reduce the water inflow in order to 

get the desired water temperature.

6.5

 

 

 

Check the Built-in ELCB as follows:

      

Pull the ELCB TEST LEVER down,

 the 

      Built-in ELCB should trip and cut off the 

      power supply, Red and Green 

      LED Indicator should light off.

     

 

      Pull the ELCB RESET LEVER down to 

      reset the ELCB,

 the 2 LED Indicator light 

      shall run ON/OFF 3 times in sequences to 

      indicate self checking and the Heater Unit 

      should resume normal function, the Green 

      LED Indicator should light on. If procedures 

      stated above prevailed, the ELCB is 

      functioning in normal condition.

.

.

 

           It is unnecessary to turn the Temperature 

Control Knob to ‘OFF’ position when the Heater 

Unit is not in use.

           Explain to the user how the unit works 

and familiarise him or her with its use.

Advise the user about possible hazards

(high water temperature)

Hand over these instructions, to be kept in a

safe place.

.

.

6.6

6.7

Read the section ‘SAFETY INFORMATION’ first.
Test the ‘ ELCB’ regularly
7.1 

Clean the 

lter regularly

7.2  Clean the Mesh Filter regularly to prevent blockage. 

When carrying out any work, isolate the unit from the mains 

and shut off the water connection.

7.3 

Cleaning precaution!

7.4  Do not use thinner, alcohol, petrol or any other 

 

organic solutions to clean the set. 

Use only dampeded cloth 

with mild detergent.

            This procedure is a highly recommended test to be 

carried out at least once a month. Turn on the power supply

and water supply, both Red (Power) and Green (ELCB)

indicators will light up if the Temperature Control Knob is in

‘ON’ position. 

Pull the ELCB TEST LEVER down, Red (Power) and Green 

(ELCB) Indicator should go off. 

Pull the ELCB RESET LEVER down

 to reset the ELCB

,resume the power supply. (Fig 8)

            If the Power Indicator does not go off when you pull

the ELCB Test lever, switch OFF the mains supply and

contact sales agent for repair service. Special skill is required

for repairing. NEVER try to repair the unit by yourself.

WARNING !

MIN. INLET WATER PRESSURE
MAX. INLET WATER PRESSURE

1.0 Bar (100kPa; 14.5 psi)
6.0 Bar (0.6 MPa ; 87.02 psi) 

Summary of Contents for EWE602IX1DWX3

Page 1: ...EN MULTI POINT ELECTRIC WATER HEATER USER MANUAL electrolux com shop EWE602IX1DWX3 EWE802IX1DWX3 ...

Page 2: ...vation In genious and stylish it has been designed with you in mind So whenever you use it you can be safe in knowledge that you ll get great results every time Welcome to Electrolux Visit our website to Get usage advice brochures trouble shooter service information www electrolux com Register your product for better service www registerelectrolux com Buy Accessories Consumables and Original spare...

Page 3: ...to be installed to conform to local regulations and ensure proper earthing grounding for ELCB to be effective NOTE When removing the Electric Water Heater from package a small amount of water may be found inside This is normal as the Electric Water Heater is tested during manufacturing process WARNING If the Electric Water Heater begins to make an odd noise smell or smoke If ELCB trips and Electri...

Page 4: ...e water supply to the Heater Unit must be free from mud and dirt Always KEEP the water supply to the Heater Unit free from mud and dirt at all time during usage Note When connecting the Pressure Relief Valve to the water inlet please make sure the discharge nozzle is facing downward Connect a discharge pipe PVC tube of dia 8 0mm to the discharge nozzle in a continuously downward direction and this...

Page 5: ...rical shock 5 3 5 4 5 5 Use double insulation cable of over 4mm 5 6 Remember to SWITCH OFF the mains before carrying out any electrical work Refer to TABLE 1 for the correct cable size Insert the wall embedded cable through Side Entry A by cutting a hole at the source cord rubber holder and lead the cable to Cable Bracket B Fig 7 WARNING 2 5 7 Connect the cable as follows Brown or Red LIVE L Blue ...

Page 6: ...lve to reduce the water inflow in order to get the desired water temperature 6 5 Check the Built in ELCB as follows Pull the ELCB TEST LEVER down the Built in ELCB should trip and cut off the power supply Red and Green LED Indicator should light off Pull the ELCB RESET LEVER down to reset the ELCB the 2 LED Indicator light shall run ON OFF 3 times in sequences to indicate self checking and the Hea...

Page 7: ...nes Inc 10th Floor W5th Avenue Building 5th Avenue Corner 32nd Street Bonifacio Global City Taguig Philippines 1634 Trunkline 63 2 737 4756 Website www electrolux com ph Email wecare electrolux com Singapore Consumer Care Center Tel 65 6727 3699 Electrolux S E A Pte Ltd 1 Fusionopolis Place 07 10 Galaxis West Lobby Singapore 138522 Office Fax 65 6727 3611 Email customer care sin electrolux com Tha...

Page 8: ...NOTE NOTE ...

Reviews: