7. TEST RUN
7.1 Turn on the water supply and 3 in 1
Stop Valve, the water will flow through the
Handshower.
7.2 Switch on the power supply. The 3
LED Indicator light shall run ON/OFF 3
times in sequences to indicate the set are
self checking.
If the
Electric Water Heater
is not earthed
properly, the Earth Led indicator light will
OFF, during usage or standby. Earth Led
indicator light also OFF if Line & Neutral
reverse connection.
7.4 The
Electric Water Heater
might not be
hot enough even at the ‘MAX’ position if
incoming water supply from the mains is too
cold or the pressure of water is too high. In
this case, you may adjust the 3 in 1 Stop Valve
to reduce the water inflow in order to get the
desired showering temperature.
7.5 Check the Built-in ELCB as following:
- Press the “TEST” Button, the Built-in ELCB
should trip and cut off the power supply,
ELCB and Power Indicators should light off.
-Press the “RESET” Button, the 3 LED
Indicator light shall run ON/OFF 3 times in
sequences to indicate self checking as in 7.2
above and the
Electric Water Heater
should
resume normal function, the Green LED
Indicator should light on. If procedures stated
above prevailed, the ELCB is functioning in
normal condition.
7.6 Move the Handshower to the desired
angle. A ratchet mechanism in the Shower
Holder will hold the Handshower in selected
position.
7.7 It is unnecessary to turn the Temperature
Control Knob to “OFF” position when the
Instant Hot Shower is not in use.
7.8 Switch OFF the power supply after shower.
(Recommended flow rate of below 6litre/min)
8. HANDSHOWER SPRAY
9. MAINTENANCE
9. MAINTENANCE - continue
Clean the Handshower Head holes by using the soft brush from time to time.
(Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during cleaning.
Fig. 8
Fig. 9
FILTER UNIT CLEANING
CLOSE
OPEN
INTERNAL
STRAINER
OPEN
CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
9.1 TEST THE ‘ELCB’ REGULARLY
(This procedure is highly recommended test at
least once a month)
9.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent
blockage (Fig. 8) . Remove the Built-in Filter by
turning its cap anticlockwise. Whenever need
Read the section ‘ SAFETY INFORMATION ’ first.
WARNING!
9.3 If the Red (POWER) Indicator does not
go off when you press the ELCB Test Button,
switch OFF the mains supply and contact
Electrolux Consumer Care Centre for repair
service. Special skill is required for repairing.
NEVER try to repair the unit by yourself.
9.4 CLEANING PRECAUTION !
Do not use thinner,alcohol,petrol or any other
organic solutions to clean the set.
Use only
damped cloth with mild detergent.
flush the internal stainer with water to remove
any trapped sediments. Whenever fixing back
the Built-In Filter, beware of the alignment of
Internal Strainer. Use the protruded guideline
within Stop Valve to position the Internal
Strainer.
10. WIRING DIAGRAM
WIRING DIAGRAM -WITH ELCB, NO PUMP DPDT MODEL
11. ELECTRICAL SPECIFICATION
Note : The specification, actual product’s cosmetic design and accessories parts shown are
correct at the time of printing and may be subjected to change without prior notice.
1.3 kg
ELECTRONIC POWER CONTROL
TYPE
L
ELECTRICA LOADING
Min. WATER FLOW RATE
WATER CONNECTION
DIMENSIONS
NETT WEIGHT
1/2” BSP SINGLE POINT
SYSTEM
6.0 Bar (0.6 MPa ;
Max. INLET WATER PRESSURE
Min. INLET WATER PRESSURE
0.1 Bar (10 kPa ;
87.02 psi)
1.45 psi)
*
Thermostat
Manual Reset (90° C Thermostat)
For Models rated 4.8kW and below, thermostat is manually resetable.
For models rated 6.0kW and above, thermostat needed to be replaced once permanently tripped.
3.5kW 15.9A 220V a.c. 50/60Hz
4.5kW 20.5A 220V a.c. 50/60Hz
2 Litre / min
CONSUMER CARE
Indonesia
Hotline service: 0
8
041119999
PT. Electrolux Indonesia
Electrolux Building
Jl.Abdul Muis No.34, Petojo Selatan,
Gambir Jakarta Pusat 10160
Email:[email protected]
SMS
&
WA : 0
8
12.
8
0
88
.
88
63
Malaysia
Consumer Care Center Tel: 1300-
88
-11-22
Electrolux Home Appliances Sdn. Bhd.
Corporate Office Address: Unit T2-7, 7th Floor, Tower 2 ,
Jaya33 Hyperoffice, No. 3, Jalan Semangat, Seksyen 13,
46100 Petaling Jaya, Selangor
Office Tel : (+60 3) 7
8
43 5999
Office Fax : (+60 3) 7955 5511
Consumer Care Center Address: Lot C6, No. 2
8
,
Jalan 15/22, Taman Perindustrain Tiong Nam,
40200 Shah Alam, Selangor
Consumer Care Center Fax : (+60 3) 5524 2521
Email : [email protected]
Philippines
Consumer Care Center Toll Free : 1-
8
00-10-
8
45-CARE 2273
Consumer Care Hotline : (+63 2)
8
45 CARE 2273
Electrolux Philippines, Inc.
10th Floor. W5th Avenue Building
5th Avenue Corner 32nd Street
Bonifacio Global City,
Taguig Philippines 1634
Trunkline: +63 2 737- 4756
Website : www.electrolux.com.ph
Email : [email protected]
Singapore
Consumer Care Center Tel: (+65) 6727 3699
Electrolux S.E.A. Pte Ltd.
1 Fusionopolis Place,
#07-10 Galaxis, West Lobby
Singapore 13
8
522.
Office Fax : (+65) 6727 3611
Email : [email protected]
Thailand
Consumer Care Tel : (+66 2) 725 9000
Electrolux Thailand Co., Ltd.
Electrolux Building 14th Floor
1910 New Phetchaburi Road,
Bangkapi, Huai Khwang, Bangkok 10310
Office Tel : (+66 2) 7259100
Office Fax : (+66 2) 7259299
Email : [email protected]
Vietnam
Consumer Care Center Toll Free : 1
8
00-5
8
-
88
-99
Tel : (+
8
4
8
) 3910 5465
Electrolux Vietnam Ltd.
Floor 9th, A
&
B Tower
76 Le Lai street - Ben Thanh Ward - District 1
Ho Chi Minh City
,
Vietnam
Office Tel : (+
8
4
8
) 3910 5465
Office Fax : (+
8
4
8
) 3910 5470
Email : [email protected]
Hongkong
Tel: (+
8
52)
8
203 029
8
Dah Chong Hong, Ltd. - Service Centre
8
/F., Yee Lim Godown Block C
2-2
8
Kwai Lok Street, Kwai Chung, N.T.
6
7
8
9
10
.
Fig 7
STANDARD SINGLE SPRAY
7.3 Turn the Temperature Control Knob to
‘ON’, the Red indicator light (HEATER POWER)
will turn on, (ELCB/Power Led indication are
combine Led indicator light- ELCB is GREEN
& Power is RED) hot water will flow out within
a few seconds. The more Temperature Control
Knob being turned in clockwise direction, the
hotter is the water.
Turn on the power supply and water supply , both
Red (HEATER) and Green (ELCB) Indicators will
light up if the Temperature Control Knob is in ‘ON’
position. Press the ELCB Test Button, both
HEATER and ELCB Indicators should go off.
Press the Reset Button to resume the power
supply.
WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with
it decades of professional experience and innovation. In genious and stylish, it has been
designed with you in mind. So whenever you use it, you can be safe in knowledge that
you’ll get great results every time. Welcome to Electrolux.
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.co.th
Register your product for better service:
https://www.electrolux.co.th/support/register-warranty/
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CONSUMER
CARE AND SERVICE
We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number.
(Right side of unit).
Warning/ Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.
LINE
NEUTRAL
Power On/Off
Temperature
Control
TRIAC
Lout
Nout
(N
in
)
(L
in
)
Auto-Reset
*
Manual-Reset
Power
Supply
220 V~a.c.
Double Action Thermostat
Electronic
ELCB,15mA
Sensitivity
Reset
Test
T2
G
Relay 1
Relay 2
Heater Control
On/Off Switch
189 (W) X 270 (H) X 102 (T) mm