Electrolux EW30EW55PS Installation Instructions Manual Download Page 3

3

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

(and Optional Electric or Gas Cooktop Combination)

Important Notes to the Installer

1.  Read all instructions contained in these installation 

instructions before installing the wall oven.

2.  Remove all packing material from the oven 

compartments before connecting the electrical 

supply to the wall oven.

3.  Observe all governing codes and ordinances.

4.  Be sure to leave these instructions with the 

consumer.

5.  Oven door may be removed to facilitate installation.

6.  THESE OVENS ARE NOT APPROVED FOR 

STACKABLE OR SIDE-BY-SIDE INSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for the 

local electrical inspector's use and future reference.

IMPORTANT SAFETY 

INSTRUCTIONS

•  Be sure your wall oven is installed and grounded 

properly by a qualified installer or service technician.

•  This wall oven must be electrically grounded in 

accordance with local codes or, in their absence, 

with the National Electrical Code ANSI/NFPA No.70- 

latest edition in United Sates, or with CSA Standard 

C22.1, Canadian Electrical Code, Part 1, in Canada.

 Stepping, leaning or sitting on the door 

of this wall oven can result in serious injuries and can 

also cause damage to the wall oven.

•  Never use your wall oven for warming or heating 

the room. Prolonged use of the wall oven without 

adequate ventilation can be dangerous.

 The electrical power to the oven must be 

shut off while line connections are being made. Failure to 

do so could result in serious injury or death.

1. Carpentry

Refer to figure 1 or 2 for the dimensions applicable to 

your appliance, and the space necessary to receive the 

oven. The oven support surface may be solid plywood 

or similar material, however the surface must be level 

from side to side and from front to rear.

2. Adjusting Oven Height

Oven height can be adjusted with 2" (5cm) wide wood 

shims when needed to fit into an existing cabinet 

cutout opening, when cutout height exceeds 

28

"

 

(71.1cm) 

for the single wall oven or 

49

1

/

8

"

 

(124.8 cm)

 for 

the double wall oven (see Figure 1 or 2). Place shims 

of appropriate height beneath the oven side rails.

3. Electrical Requirements

This appliance must be supplied with the proper 

voltage and frequency, and connected to an individual, 

properly grounded branch circuit, protected by a circuit 

breaker or fuse. To know the circuit breaker or fuse 

required by your model, see the serial plate to find the 

wattage consumption and refer to table A to get the 

circuit breaker or fuse amperage.

Table A

Observe all governing codes and local ordinances

1. A 3-wire or 4-wire single phase 120/240 or 120/208 

Volt, 60 Hz AC only electrical supply is required on a 

separate circuit fused on both sides of the line (red 

and black wires). A time-delay fuse or circuit breaker 

is recommended. DO NOT fuse neutral (white wire). 

Only certain cooktop models may be installed over 

certain built-in electric oven models. Approved 

cooktops and built-in ovens are listed by the MFG 

ID number (see the insert sheet included in the 

literature package).

NOTE: Wire sizes and connections must conform with 

the fuse size and rating of the appliance in accordance 

with the American National Electrical Code ANSI/NFPA 

No. 70-latest edition, or with Canadian CSA Standard 

C22.1, Canadian Electrical Code, Part 1, and local 

codes and ordinances.

 An extension cord should not be used 

with this appliance. Such use may result in a fire, 

electrical shock, or other personal injury. If you need a 

longer power cord you can purchase a 10' (3 m) power 

cord kit #903056-9010 by calling the Service Center.
2.  These appliances should be connected to the 

fused disconnect (or circuit breaker) box through 

flexible armored or nonmetallic sheathed cable. 

The flexible armored cable extending from the 

appliance should be connected directly to the 

junction box. The junction box should be located 

as shown in Figure 1 or Figure 2 and with as much 

slack as possible remaining in the cable between 

the box and the appliance, so it can be moved if 

servicing is ever necessary.

3.  A suitable strain relief must be provided to attach 

the flexible armored cable to the junction box.

Appliance 

Rating Watts

240V

Protection 

Circuit 

Recommended

Appliance 

Rating Watts

208V

Protection 

Circuit 

Recommended

Less than 

4800W

20A

Less than 

4100W

20A

4801W - 7200W

30A

4101W - 6200W

30A

7201W - 9600W

40A or 50A

6201W - 8300W

40A or 50A

9601W and +

50A

8301W and +

50A

Summary of Contents for EW30EW55PS

Page 1: ... or if noise is heard on convection models verify dimension G to assure it is the required depth 4 For a cutout height greater than 28 71 1 cm add one 2 5 cm wide wood shim of appropriate height to each side of the Suggested distance from floor is 31 78 7cm Minimum required distance is 4 11 4cm INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL ...

Page 2: ...sure it is according to the required dimension 4 For a cutout height greater than 49 3 8 125 4 cm add a 2 5 cm wide wood shim of appropriate height to each side of the opening under the appliance side rails 5 For a cutout height H greater than 50 1 8 127 3 cm you can order a larger bottom trim through a Service Center All dimensions are in inches cm B A D F I H G C 48 5 8 123 5 cm 11 29 2 cm 2 5 1...

Page 3: ...eath the oven side rails 3 Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage...

Page 4: ...ranch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 4 If your appliance is to be connected to a ...

Page 5: ... In the junction box connect appliance and power supply cable wires as shown in Figure 4 Figure 4 4 WIRE GROUNDED JUNCTION BOX Cable from Power Supply White Wire Junction Box Cable from appliance White Wire Black Wires Red Wires Ground Wire Ground Wire Bare or Green Wire U L Listed Conduit Connector or CSA listed Heavy Weight Hazard Use 2 or more people to move and install wall oven Failure to fol...

Page 6: ...onal injury and may damage cabinetry or the appliance Screws to attach the bottom trim are supplied with the oven Screws are located in the mounting holes located on each side trim below the oven frame see Figure 7 A Remove the screws from the mounting holes B Place the top of the bottom trim over the side trim tabs on each side of the oven below the oven door C Attach the trim using the provided ...

Page 7: ... installed directly over the oven unit 5 12 7 cm maximum is allowed above the floor 208 240 Volt junction box for built in oven Figure 8 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE Approx 3 7 5 cm Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installat...

Page 8: ... the upper element in the oven should become red Convection some models When the oven is set for a convection baking or roasting both elements cycle on and off alternately and the convection fan will run The convection fan will stop running when the oven door is opened Before You Call for Service Read the Before You Call for Service Checklist and the Operating Instructions in your Use and Care Gui...

Page 9: ...PARA SU SEGURIDAD No almanece ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de este o de cualquier otro artefacto El primer paso para su instalación debe de ser el de medir las dimensiones de la apertura y compararlas con las que se indican en el cuadro de dimensiones del hueco de la figura 1 Posiblemente encontrará que algún trabajo de carpintería será necesario LA I...

Page 10: ...eles laterales del accesorio 5 Para un corte de una altura H mayor que 501 8 127 3 cm una moldura grande inferior puede ser pedido con su representante No quite los separadores de los muros laterales del horno empotrado Estos espaciadores centran el horno en el espacio provisto El horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor ...

Page 11: ... cuñas de altura apropiada debajo de los rieles laterales del horno 3 Requerimientos Eléctricos Se debe proveer el voltaje y la frecuencia apropiados a este electrodoméstico y conectarse a un circuito individual correctamente puesto a tierra protegido por un interruptor o un fusible Para conocer el interruptor o fusible que requiere su modelo vea la placa serial para encontrar la consumación del v...

Page 12: ...tierra debe conectarse al terminal de puesta a tierra o el alambre conductor en al aparato No utilice el suministro de gas para hacer la puesta a tierra La falta de cualquiera de las instrucciones mencionadas podría resultar en un incendio choque eléctrico o lesiones personales Figura 3 CAJA DE EMPALMES DE 3 ALAMBRES PUESTA A TIERRA Cable desde el suministro de energía Cable de la estufa Alambre d...

Page 13: ...3 En el caja de juntas conectar el aparato y los cables residenciales como se muestra en la figura 4 Figura 4 CAJA DE EMPALMES DE 4 ALAMBRES PUESTA A TIERRA Alambre desnudo Cable desde el suministro de energía Alambre verde o desnudo Cable de la estufa Caja de empalmes Conductor de unión listado UL o CSA Alambre blanco Alambre rojos Alambre negros Alambre blanco IMPORTANTE No levante o manipular e...

Page 14: ...ica tambien puede dañar el gabinete o puede causar daños el aparato electrodoméstico Los tornillos para instalar la guarda de seguridad inferior son proporcionados con el horno Los tornillos se encuentran en los orificios de montaje localizados en cada lado debajo del marco del horno ver Figura 7 A Quite los tornillos que se encuentran en los orificios de montaje B Colocar la guarda de seguridad i...

Page 15: ...son necesarios para aislar la unidad de los gabinetes adyacentes La altura del relleno lateral del gabinete debe permi tir la instalación de modelos de tapas de cocina aprobados 27 68 6 cm Horno de pared 30 76 2 cm Horno de pared DIMENSIONES DE ABERTURA F ANCHURA 247 8 63 2 cm Min 251 4 64 1 cm Max 281 2 72 4 cm Min 29 73 7 cm Max G PROFUNDIDAD 231 2 59 7 cm Min 231 2 59 7 cm Min H ALTURA 271 4 69...

Page 16: ... tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricación de este artefacto Lea la garantía y la información sobre el servicio en su Manual del Usuario para obtener el número de teléfono gratuito IMPORTANTE Un ventilador ubicado dentro de la parte trasera superior arriba del horno en algunos modelos permite la refrigeración de los compo...

Page 17: ... que 28 71 1 cm ajoutez une entretoise de bois de 2 5 cm de largeur et Imprimé au U S A de hauteur appropriée de chaque côté de l ouverture sous l appareil 5 Si la hauteur de découpage H est plus grande que 283 4 73 cm vous pouvez commander une assiette plus bas à travers un centre de service La distance suggérée du plancher est 31 78 7 cm La distance minimale requise est 41 2 11 4 cm L INSTALLATI...

Page 18: ...endre sur les modèles à convection vérifiez la dimension G pour vous assurer qu elle est correcte 4 Si la hauteur de découpage est plus grande que 493 8 125 4 cm ajoutez une entretoise de bois de 2 5 cm de largeur et de hauteur appropriée de chaque côté de l ouverture sous l appareil 5 Si la hauteur de découpage H est plus grande que 501 8 127 3 cm vous pouvez commander une moulure inférieure plus...

Page 19: ...e ou 491 8 124 8 cm pour un four encastré double voir la figure 1 ou 2 Placez l entretoise de hauteur appropriée de chaque côté de l ouverture sous l appareil 3 Exigences électriques Ces appareils doivent être branchés à une alimentation possédant la tension et la fréquence appropriées Ils doivent être connectés à un circuit dédié correctement mis à la terre et protégé par un disjoncteur ou un fus...

Page 20: ...appareil est obligatoire Ne branchez pas l appareil au circuit électrique tant qu il ne sera pas mis à la terre correctement et en permanence Coupez l alimentation à la boîte de jonction avant de faire les raccords électriques Cet appareil doit être connecté à un circuit permanent électrique métallique et mis à la terre ou à un connecteur de mise à la terre qui doit être branché à la borne ou au f...

Page 21: ...figure 4 Emplacement des numéros de modèle et de série La plaque signalétique est située sur le côté intérieur de la moulure latérale Pour toute commande de pièces ou demande de renseignement au sujet de votre appareil assurez vous d inclure les numéros de modèle et de série ainsi que le numéro ou lettre de lot de la plaque signalétique de votre four Risque de lourde charge Soyez 2 personnes ou pl...

Page 22: ... sur les moulures latérales sous l encadrement du four voir Figure 7 A Retirez les vis des trous de montage B Placez le dessus de la moulure inférieure par dessus les pattes des moulures latérales de chaque côté du four sous la porte du four C Fixer la moulure en utilisant les vis fournies Risquedebasculement Trous de montage du dispositif anti renverse ment Pour une installation adéquate du dispo...

Page 23: ...ur encastré 30 76 2 cm 247 8 63 2 cm Min 251 4 64 1 cm Max 281 2 72 4 cm Min 29 73 7 cm Max 231 2 59 7 cm Min 231 2 59 7 cm Min 271 4 69 2 cm Min 28 71 1 cm Max 271 4 69 2 cm Min 28 71 1 cm Max Pour réduire les risques de blessures et pour empêcher le four encastré de basculer Utilisez les supports de fixation pour retenir le four encastré à l armoire Utilisez un contre plaqué de 1 9 cm d épaisseu...

Page 24: ... l appareil et ce jusqu à ce que les composantes aient refroidi 7 Vérification du fonctionnement Si votre appareil possède une commande électronique de four Toutes les fonctions qu elle contrôle ont été vérifiées en usine pour leur bon fonctionnement avant que l appareil soit expédié Cependant nous vous suggérons de vérifier à nouveau le fonctionnement de la commande électrique Reportez vous à vot...

Reviews: