background image

30" Combination Installation Specifications

Always consult local and national electric codes. 

(Refer to product-specific electrical specifications on this page.)

Minimum 23-5/8" deep cutout dimension is critical for proper
combination installation, to ensure that each built-in product’s faceplate
will fit flush against cabinet front.

Bases must be level and cabinet front must be square.

Minimum 4-1/2" required distance from bottom of Warmer Drawer cutout 
to floor.

Respect critical dimensions as noted for proper installation of built-In
products.

Minimum 21" clearance needed for Wall Oven door depth when open.

30" Built-In Microwave Specifications

Product Weight – 48 Lbs.

Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

Connected Load (kW Rating) @ 120 Volts = 1.5 kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120 Volts = 13 Amps

Full oven base of solid plywood or similar material required, capable 
of supporting 100 Lbs.

Minimum 2-7/8" clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap
between both product faceplates. 

30" Electric Single Wall Oven Specifications

Product Weight – 200 Lbs.

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 
AC only electrical supply with ground required on separate circuit fused
on both sides of line.

Connected Load (kW Rating) @ 240 / 208 Volts = 4.0 / 3.0 kW

Amps @ 240 / 208 Volts = 17.0 / 14.5 Amps

To support Wall Oven, two 3"-wide x 3/4"-thick planks must be installed
as a base, capable of supporting 200 Lbs. Do NOT use full base, since
planks are necessary to allow for proper air displacement. 

30" Warmer Drawer Specifications

Product Weight – 65 Lbs.

Voltage Rating – 120V / 450W / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.45 kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120V =  3.75 Amps

Full base of solid plywood or similar material required, capable of
supporting 100 Lbs. 

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxappliances.com for detailed instructions.

30" Combination Installation –

Built-In Microwave/Single Wall Oven/Warmer Drawer

High standards of quality at Electrolux Home Products, Inc. mean 

we are constantly working to improve our products. We reserve the right 

to change specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

10200 David Taylor Drive 

Charlotte, NC 28262 

1-877-4electrolux (1-877-435-3287) 

electroluxappliances.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxappliances.ca

MOSS_EW_WD 30INST EL  07/11

© 2011 Electrolux Major Appliances, NA

Printed in the U.S.A.

Summary of Contents for EW30EW55G - 30 in. Single Wall Oven

Page 1: ...ck Additional Features Signature Soft Arc Oven Door and Handle Design Luxury Hold Oven Door Extra Large Glass Window Sabbath Mode Star K Certified A D A Compliant Accessories Porcelain Broiler Pan and Insert 3 high Bottom Trim S PN 903114 9110 W PN 903114 9101 B PN 903114 9100 Specifications Color Stainless Steel White Black Oven Cavity Dimensions Height Width Depth Product Dimensions Height Inclu...

Page 2: ...lways consult local and national electric codes Minimum 21 clearance for oven door depth when open Suggested distance from floor is 31 Minimum required distance is 4 1 2 Minimum 23 1 2 deep cutout dimension is critical for proper installation to ensure that oven s faceplate will fit flush against cabinet front To adapt oven to fit cutout height between 27 5 8 and 28 1 4 add one 2 wide wood shim of...

Page 3: ... EW30EW55G EI30EW35J EI30EW35K EW27EW55G EI27EW35J and EI27EW35K are approved to be used beneath Electrolux cooktop models EW36EC55G EW30EC55G EW36IC60I EW30IC60I EW36CC55G and EW30CC55G For detailed Electric or Induction Hybrid Cooktop installation refer to model specific product page and installation guide on web Side filler panels necessary to isolate oven from adjoining cabinets Panel height m...

Page 4: ...models EW36GC55G EW30GC55G and EW30GC60I For detailed Gas Cooktop installation refer to model specific product page and installation guide on web Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommodate the depth of approved gas cooktop models Minimum height opening of 6 1 2 from top of counter required in right cabinet side panel and...

Page 5: ... 200 Lbs Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line Connected Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 17 0 14 5 Amps Full oven base of solid plywood or similar material required capable of supporting 200 Lbs To adapt oven to fit cutout height between 27 5 8 and 28 1...

Page 6: ...lt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line Connected Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 17 0 14 5 Amps To support Wall Oven two 3 wide x 3 4 thick planks must be installed as a base capable of supporting 200 Lbs Do NOT use full base since planks are necessary to allow for proper air displacement 30 Warmer Drawer...

Page 7: ...ht 200 Lbs Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line Connected Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 17 0 14 5 Amps Full oven base of solid plywood or similar material required capable of supporting 200 Lbs To adapt oven to fit cutout height between 27 5 8 and 28...

Page 8: ...Volt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line Connected Load kW Rating 240 208 Volts 4 0 3 0kW Amps 240 208 Volts 17 0 14 5 Amps To support Wall Oven two 3 wide x 3 4 thick planks must be installed as a base capable of supporting 200 Lbs Do NOT use full base since planks are necessary to allow for proper air displacement 30 Warmer Draw...

Page 9: ...SA 10200 David Taylor Drive Charlotte NC 28262 1 877 4electrolux 1 877 435 3287 electroluxappliances com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxappliances ca INSTGDLNS_SSR EL 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to instal...

Page 10: ...A 10200 David Taylor Drive Charlotte NC 28262 1 877 4electrolux 1 877 435 3287 electroluxappliances com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxappliances ca INSTGDLNS_FDR EL 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to install...

Reviews: