30" Dual-Fuel Freestanding Range Specifications
•
Product Weight – 260 Lbs.
•
Electrical Requirements – 240 Volts AC, 4-wire, 60 Hertz, 50 Amps
Dedicated Circuit
•
Connected Load (kW Rating) @ 240 Volts = 4.4kW
•
Amps @ 240 Volts = 18.3 Amps
•
Always consult local and /or national electric and gas codes.
•
Range ships with 3/4" factory regulator.
•
Range is NOT Lp convertible — for Lp-only models see EW3LDF65GS,
EW3LDF65GW and EW3LDF65GB.
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Allow 30" minimum clearance between top of rangetop and bottom of
unprotected wood or metal overhead cabinetry.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
•
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
•
Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.
•
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•
Wok Ring – (318254307).
•
Simmer Plate – (318254206).
Dual-Fuel Freestanding Ranges
EW30DF65G S, EW30DF65G W, EW30DF65G B
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
•
250 Bobby Jones Expressway
•
Augusta, GA 30907
•
1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxappliances.ca
EW30DF65G 01/08
© 2008 Electrolux Major Appliances, NA
Printed in the U.S.A.
28
5
/
8
"
26
3
/
8
"
Side
Gas
connection
and power
supply
location
(right bottom
rear)
Overall depth
including oven
door in 90
°
open
position – 47"
35
7
/
8
"
Adjustable
to
36
1
/
8
"
11
5
/
8
"
47
1
/
2
"
Front
29
7
/
8
"
5" min.
to nearest
combustible
wall (either
side of unit)
above 36"
height
30" min.
13"
max.
25"
24"
30
1
/
8
"
2"
15"
11
1
/
2
"
Area allows for flush
installation with through-
the-floor connection
of pipe stub/shutoff valve
Area allows for flush
installation with through-
the-wall connection of
pipe stub/shutoff valve
and rear wall 240V outlet
CL
10
1
/
2
"
7"
23"
18" min.
36"
stand.
34"