background image

30" Dual-Fuel Freestanding Range Specifications

Product Weight – 260 Lbs.

Electrical Requirements – 240 Volts AC, 4-wire, 60 Hertz, 50 Amps
Dedicated Circuit

Connected Load (kW Rating) @ 240 Volts = 4.4kW

Amps @ 240 Volts = 18.3 Amps

Always consult local and /or national electric and gas codes.

Range ships with 3/4" factory regulator. 

Range is NOT Lp convertible — for Lp-only models see EW3LDF65GS,
EW3LDF65GW and EW3LDF65GB.

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between top of rangetop and bottom of
unprotected wood or metal overhead cabinetry.

Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.

Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.

Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.

To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

Wok Ring – (318254307).

Simmer Plate – (318254206).

Dual-Fuel Freestanding Ranges

EW30DF65G S, EW30DF65G W, EW30DF65G B

High standards of quality at Electrolux Major Appliances mean we are 

constantly working to improve our products. We reserve the right to change 

specifications or discontinue models without notice.

USA

250 Bobby Jones Expressway 

Augusta, GA 30907 

1-877-4electrolux (1-877-435-3287) 

electroluxappliances.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxappliances.ca

EW30DF65G 01/08

© 2008 Electrolux Major Appliances, NA

Printed in the U.S.A.

28

5

/

8

"

26

3

/

8

"

Side

Gas

connection

and power

supply

location

(right bottom

rear)

Overall depth

including oven

door in 90

°

open

position – 47"

35

7

/

8

"

Adjustable

to

36

1

/

8

"

11

5

/

8

"

47

1

/

2

"

Front

29

7

/

8

"

5" min.
to nearest
combustible
wall (either
side of unit)
above 36"
height

30" min.

13"

max.

 25"

24"

30

1

/

8

"

2"

15"

11

1

/

2

"

Area allows for flush

installation with through-

the-floor connection

of pipe stub/shutoff valve

Area allows for flush

installation with through-

the-wall connection of

pipe stub/shutoff valve

and rear wall 240V outlet

CL

10

1

/

2

"

7"

23"

18" min.

36"

stand.

34"

min.

Reviews: