Component Teardown
4-8
Door Adjustment
When removing and/or loosening the oven hinges such
as in door replacement, the following adjustment criteria
are taken.
Door adjustment is performed with the door properly
installed and closed and while the oven hinges are loose.
1. Loosen screws holding the oven hinge right and the
oven hinge left to the bottom plate with screwdriver.
2. Adjust door by moving it so that the door is parallel
with the oven cavity front plate lines (right and left
side lines) and the door latch heads pass through the
latch holes correctly.
3. Tighten the screws holding the oven hinge right and
the oven hinge left to the bottom plate.
After adjustment, make sure of the following:
1. The door latch heads smoothly catch the latch hooks
through latch holes and the latch heads goes through
center of latch holes.
2. The door is positioned with its face pressed toward
oven cavity front plate.
3. Reinstall outer case cabinet and check for microwave
leakage around the door with an approved microwave
survey meter. (Refer to Microwave Measurement
Procedure.)
Door Disassembly
1. Disconnect the power supply cord and remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the door assembly, referring to “Door
Replacement”.
5. Place the door assembly on a soft cloth with latch
heads facing up.
NOTE:
As the engaging part of choke cover and door
frame are provided at 16 places, do not force any
particular part.
6. Replacement of the door components are as follows:
CHOKE COVER
7. Insert a putty knife (thickness of about 0.5mm) into
the gap A between the choke cover and door stopper
and between the choke cover and the door frame as
shown in Figure 4-7 to free engaging parts.
8. Pry the choke cover by inserting a putty knife in order
shown in Figure 4-7.
9. Now choke cover is free from door panel and door
frame.
Choke
Cover
Door
Frame
Door Panel
Assembly
Putty Knife
Figure 4-7. Door Disassembly
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of
the high-voltage capacitor (that is the connecting
lead of the high-voltage rectifier) against the
chassis with the use of an insulated screwdriver.