5
Water drainage
The end of the drain hose can be positioned in three
ways:
Hooked over the edge
of a sink using the
plastic hose guide sup-
plied with the machine.
In this case, make sure
the end cannot come
unhooked when the
machine is emptying.
This could be done by
tying it to the tap with a
piece of string or attaching it to the wall.
In a sink drain pipe branch. This branch must be
above the trap so that the bend is at least 60 cm
above the ground.
Directly into a drain pipe at a height of not less than
60 cm and not more than 90 cm.
The end of the drain hose must always be ventilated,
i.e. the inside diameter of the drain pipe must be larg-
er than the outside diameter of the drain hose.
The drain hose must not be kinked. Run it along the
floor; only the part near the drainage point must be
raised.
P0023
P0022
Electrical connection
This machine is designed to operate on a 220-230 V,
single-phase, 50 Hz supply.
Check that your domestic electrical installation can
take the maximum load required (2.2 kW), also taking
into account any other appliances in use.
Connect the machine to an earthed socket, in accor-
dance with current wiring regulations.
The manufacturer declines any responsibility for
damage or injury through failure to comply with
the above safety precaution.
Summary of Contents for EW 1262 W
Page 16: ...124978740 Z ...