7

It is important to periodically clean the defrost
water drain hole (F) situated under the salad
drawers to prevent the water overflowing and
dripping onto the food inside. Use the special
cleaner provided (P), which you will find already
inserted into the drain hole.

4. when defrosting is completed, dry the interior

thoroughly and refit the plug.

5. Turn the thermostat knob back to the required

setting or replace the plug in the power socket. 

Important
Never use sharp metal tools to scrape off
frost from the evaporator as you could
damage it.
Do not use a mechanical device or any
artificial means to speed up the thawing

process other than those recommended by
the manufacturer.
A temperature rise of the frozen food
packs, during defrosting, may shorten their
safe storage life.

Periods of non-operation

When the appliance is not in use for long periods,
take the following precautions:
¥ remove the plug from the wall socket;
¥ remove all food:
¥ defrost and clean the interior and all accessories;
¥ leave the door ajar to allow air to circulate to

prevent unpleasant smells.

The freezer compartment, however, will become
progressively covered with frost. This should be
removed with a plastic scraper, whenever the
thickness of the frost exceeds 4 mm. During this
operation it is not necessary to switch off the power
supply or to remove the foodstuffs.

However, when the ice becomes very thick on the
inner liner, complete defrosting should be carried out
as follows:
1. pull out the plug from the wall socket or turn the

thermostat knob to the ÇOÈ setting;

2. remove any stored food, wrap it in several layers

of newspaper and put it in a cool place;

3. leave the door open, place a basin on the top shelf

of the refrigerator compartment, under the drain
hole, remove the plug as shown in the figure;

PR151

S.I.011

P

F

Periodic cleaning

Never use metal objects for clearing your
appliance as it may get damaged.

Clean the inside with warm water and bicarbonate of
soda. Rinse and dry thoroughly.

The appliance is equipped with a ventilation grid.
Keep clean to guarantee good ventilation and good
working order of the appliance.
An accumulation of dust will affect the performance
of the appliance and cause excessive electricity
consumption.

The structure of the appliance permits cleaning of the
rear zone close to the wall, using a vacuum cleaner.

1. Remove the plinth (1), then the ventilation grid (2);

2. Carefully pull the air deflector out (3), checking

that there is no water left from the defrosting.

S.I.013

3

2

1

Summary of Contents for ERU1371

Page 1: ...BUILT IN REFRIGERATORS REFRIGERADORES UMBUTíVEIS 2222 685 40 ERU 1371 r e f r i g e r a t o r f r i g o r í f i c o P GB ...

Page 2: ...ass of this appliance the following instructions must be observed when the ambient temperature drops below the minimum level the storage temperature in the freezer compartment cannot be guaranteed therefore it is advisable to use the food stored as soon as possible Frozen food must not be re frozen once it has been thawed out ManufacturersÕ storage recommendations should be strictly adhered to Ref...

Page 3: ... disposal sites may be obtained from your municipal authorities The materials used on this appliance marked with the symbol are recyclable Contents Important Safety Instructions 2 Use Cleaning the interior Starting up Temperatur control Fresh food refrigeration 4 Freezing fresh food Storage of frozen food Thawing 4 Ice cube production Movable shelves Positioning the door shelves Explanation of the...

Page 4: ...automatic defrosting and so a saving in electricity consumption Fresh food refrigeration The refrigerator compartment is suitable for cooling drinks and for normal food storing To obtain the best performance do not store warm food or evaporating liquids in the refrigerator cover or wrap up the food particularly if it has a strong smell Cleaning the interior Before using the appliance for the first...

Page 5: ...rs so that the shelves can be positioned as desired For better use of space the front half shelves can lie over the rear ones D338 The glass shelf above the vegetable drawers and the bottle shelf should always remain in position to ensure correct air circulation Positioning the door shelves This model is equipped with a variable storage box which is fitted under a door shelf compartment and can be...

Page 6: ...ans Defrosting Frost is automatically eliminated from the evaporator of the refrigerator compartment every time the motor compressor stops during normal use The defrost water drains out through a trough into a special container at the back of the appliance over the motor compressor where it evaporates Hints for storage of frozen food To obtain the best performance from this appliance you should ma...

Page 7: ...This should be removed with a plastic scraper whenever the thickness of the frost exceeds 4 mm During this operation it is not necessary to switch off the power supply or to remove the foodstuffs However when the ice becomes very thick on the inner liner complete defrosting should be carried out as follows 1 pull out the plug from the wall socket or turn the thermostat knob to the ÇOÈ setting 2 re...

Page 8: ...electricity supply find out by plugging in another appliance the thermostat knob is in the correct position If there are water drops on the bottom of the cabinet check that the defrost water drain opening is not obstructed see Defrosting section If your appliance is still not working properly after making the above checks contact the nearest service centre To obtain fast service it is essential th...

Page 9: ... cabinet In that case wait for the natural fitting of the gasket or accelerate this process by heating up the part involved with a normal hairdrier Installation Positioning The appliance should be installed well away from sources of heat such as radiators boilers direct sunlight etc Best performance is obtained with ambient temperature between 18 C and 43 C class T 18 C and 38 C class ST 16 C and ...

Page 10: ...e to radio interference suppression 73 23 EEC of 19 2 73 Low Voltage Directive and subsequent modifications 89 336 EEC of 3 5 89 Electromagnetic Compatibility Directive and subsequent modifications Grid preparation Left door opening Remove the left side A of the grid cutting it from the rear see figure Right door opening Remove the right side B of the grid cutting it from the rear see figure DO002...

Page 11: ...Kitchen aperture To fit these brackets remove the two screws at the top left and right hand front corners of the cabinet Position the two brackets as shown in the figure and replace the two securing screws If necessary pads E are supplied for the rear feet to make sliding the appliance in and out of the recess easier To fit the pads press them onto the rear feet 4 The joint cover B is to be assemb...

Page 12: ...10 1 2 3 4 C 6 6 To mount the furniture door proceed as shown in the figures 7 a b c C click click 8 b 9 I c Möbeltür Innenseite a Upper part of kitchen furniture panel I 27 5 cm 27 5 cm 55 cm 10 F 1 2 3 45 11 ...

Page 13: ...s The same applies to an opening height dimension B 870 mm and a plinth height dimension b 150 mm For plinth heights greater than a 100 mm b 150 mm a cut should be made in the plinth 580 mm wide in the centre of the appliance position leaving a remaining height of a 100 mm b 150 mm Attach plinth to the kitchen units Important The plinth must be positioned at a minimun distance of 25 mm from the do...

Page 14: ...ELECTROLUX HOME PRODUCTS OPERATIONS EUROPE ...

Reviews: