19
Too much carbon dioxide in
the water
Dilute with ordinary water. (See the section
"The water dispenser functions")
No carbon dioxide.
The gas cylinder is empty. Replace the gas
cylinder.
Drain off a large amount of carbonated water
(about 1 litre)
Incoming water pressure too low.
Water flow very low
Remove and clean the strainer in the
connecting valve.
Sediment in the water. Replace the filter or
install a pre-filter.
Only gas comes out when
opening
Incoming water pressure too high. Install a
pressure-limiting device.
Capacity temporarily exceeded. Wait for ten
minutes.
The water dispenser lamp
flashes
Leakage at the water connection. Remedy
the leakage and empty the box by pulling out
the red plug.
See the illustration in "Connecting the water
hose".
The indicator lamp flashes.
The filter has been totally utilised. Replace the
filter.
The indicator lamp stays on
and shows yellow
80 % of the filter capacity expended. Buy a
new filter.
Delivery is interrupted after a
short time
The maximum time of two minutes is
attained. Continue with delivery.
If after above checksthere is still a fault call your local Service Force Centre.
In-guarantee customers should ensure that the above checks have been made
as the engineer will make a charge if the fault is not a mechanical or electrical
breakdown.
Please note that proof of purchase is required for in-guarantee service calls.