Undercounter in column:
58.0 cm
Width
56.0-57.0 cm
Depth
min. 55.0 cm
Useful dimensions of oven recess
Height
33.5 cm
Width
39.5 cm
Depth
41.0 cm
Installation
Connecting to the electrical supply
Warning!
Installation and connection
must be done in compliance with the
regulations in force. Any interventions
must be carried out when the appliance
is switched off. Only accredited
engineers may work on the appliance.
The manufacturer disclaims any liability
if the safety measures are not observed.
Before connecting to the electrical supply,
please make sure:
• The fuse and the domestic electrical in-
stallation must be designed for the max.
load of the appliance (see rating plate).
• The domestic electrical installation must
be equipped with a proper earth connec-
tion in accordance with the regulations in
force.
• The socket or the multi-pole off switch
must be easy to access after the appliance
has been installed.
The appliance is supplied with a power cable.
The cable must be equipped with a standard
plug suitable for the load indicated on the
rating plate. The plug must be inserted in a
suitable power socket. If you require a direct
connection to the electric network (mains), it
will be necessary to fit between the appliance
and the mains an omnipole switch, with a
minimum gap between contacts of 3 mm,
suitable for the required load and in compli-
ance with rules in force. The green & yellow
ground wire must not be interrupted by the
switch and it should be 2-3 cm. longer than
the other cables.
The mains cable and plug are to be connec-
ted to a shockproof socket (230 V~, 50 Hz).
The shockproof socket must be installed in
accordance with the regulations.
The following types of mains cable are suit-
able, taking the necessary rated cross sec-
tion into account: H07 RN-F, H05 RN-F, H05
RR-F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
The connection cable must in any case be
laid out so that at no point does it reach 50°C
(over room temperature).
After the connection has been carried out,
the heating elements must be tested by be-
ing operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible
terminal block which is designed to operate
with a single phase power supply of 230 V.
Letter L
Live terminal
Letter N
Neutral terminal
or E
Earth terminal
Building In
For problem-free functioning of the built-in
appliance, the kitchen unit or the recess into
which the appliance is built must have suita-
ble dimensions.
In accordance with the regulations in force,
all parts which ensure the shock protection
of live and insulated parts must be fastened
in such a way that they cannot be undone
without tools.
These also include the fixing of any end walls
at the beginning or end of a line of built-in
units.
14