Connecting to the electrical supply
Before connecting to the electrical
supply, please make sure:
-
The fuse and the domestic electrical
installation must be designed for the
max. load of the appliance (see rating
plate).
-
The domestic electrical installation
must be equipped with a proper earth
connection in accordance with the
regulations in force.
-
The socket or the multi-pole off switch
must be easy to access after the
appliance has been installed.
This appliance is delivered with an elec-
tric supply cable.
A proper plug, according to the elec-
tric load specified on the rating plate,
must be fitted to the cable. The plug is
to be inserted into a suitable wall socket.
If you require a direct connection to the
electric network (mains), it will be nec-
essary to fit between the appliance and
the mains an omnipole switch, with a
minimum gap between contacts of 3
mm, suitable for the required load and in
compliance with rules in force. The green
& yellow ground wire must not be inter-
rupted by the switch and it should be 2-
3 cm. longer than the other cables.
The mains cable and plug as sup-
plied are to be connected to a shock-
proof socket (230 V~, 50 Hz). The shock-
proof socket must be installed in accor-
dance with the regulations.
The following types of mains cable
are suitable, taking the necessary rated
cross section into account: H07 RN-F,
H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
The connection cable must in any
case be laid out so that at no point does
it reach 50°C (over room temperature).
After the connection has been carried
out, the heating elements must be tested
by being operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible
terminal block which is designed to
operate with a single-phase power
supply of 230 V.
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E - Earth terminal