![Electrolux EMS2685 Service Manual Download Page 28](http://html.mh-extra.com/html/electrolux/ems2685/ems2685_service-manual_96839028.webp)
SOI 03.06 FV
28/38
599 36 78-45
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below
before operating the oven.
1. CARRY OUT 3D CHECKS.
2. Make sure that a definite "click" can be heard
when the microwave oven door is unlatched.
(Hold the door in a closed position, then
push the door open button slowly. This
causes the latch heads to rise, it is then
possible to hear a "click" as the door
switches
operate.)
3. Visually check the door and cavity face plate
for damage (dents, cracks, signs of arcing
etc.).
Carry out any remedial work that is necessary
before operating the oven.
Do not operate the oven if any of the following
conditions exist;
1. Door does not close firmly.
2. Door hinges or latch hook is damaged.
3. The door seal is damaged.
4. The door is bent or warped.
5. There are defective parts in the door interlock system.
6. There are defective parts in the microwave
generating and transmission assembly.
7. There is visible damage to the oven.
Do not operate the oven:
1. Without the RF gasket (Magnetron).
2. If the wave guide or oven cavity are not intact.
3. If the door is not closed.
4. If the outer case (cabinet) is not fitted.
Please refer to ‘OVEN PARTS, CABINET PARTS, DOOR PARTS’, when carrying out any of the following
removal procedures:
BUILT IN FRAME ASSEMBLY REMOVAL
To remove the built in frame assembly, proceed
as follows.
1. Remove the four screws securing the frame
assembly to the oven cavity, (two from the
top and two from the hinge side).
2. Remove the two screws securing the frame
assembly to the control panel frame
(accessed from the back of the frame).
3. Open the oven door fully.
4.
Un-clip the built in frame assembly at the
bottom.
5. Pull the built in frame assembly away from the cavity
face
6. Now the built in frame assembly is free.
OUTER CASE REMOVAL
6. Slide the entire case back about 3cm to free it from
the retailing clips on the cavity face plate.
7. Lift the entire case from the oven.
8. Discharge the H.V capacitor before carrying any further
work.
9. Do not operate the oven with the outer case
removed.
To remove the outer case, proceed as follows.
1. Disconnect oven from power supply.
2. Open door and wedge open.
3. Remove the two screws from the rear
intake
duct.
4. Slide the rear intake duct up and pull it
away from the oven cavity.
5. Remove the screws from the rear(4), along
the side edges(4 hinge side, 3 control panel
side) and from the top(2 control panel side).
CAUTION: DISCHARGE HIGH VOLTAGE
CAPACITOR BEFORE TOUCHING ANY
OVEN
COMPONENTS
OR
WIRING.
TOP
SCREWS
C.P. SECURING
SCREWS
HINGE SIDE
SCREWS