Refreshment Center
Motorfan
Function:
It moves the fan that refrigerate the condenser in the cooling unit
Technical data:
Electric connectors: FASTOM
Resistance: 0,85K
Ω
Pressure switch
Function:
Feels the pressure of a gas and it gives a signal to the main board
when arrived to the programmed value.
Technical data:
T 1.5 NA-20/06
Electric connectors: FASTOM
Resistance: none
Main board
Function:
Controls all sensors and probes, and decides to switch on or off
all components plugged to it when its software says so.
Technical data:
Ref.:
Power connectors: none
Resistance: 0,82K