background image

Gas Built-In Range

EI30GS55J S

Electrolux Major Appliances, N.A.

USA

250 Bobby Jones Expressway 

Augusta, GA 30907 

1-877-4electrolux (1-877-435-3287) 

electroluxappliances.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxappliances.ca

EI30GS55J  01/10

© 2010 Electrolux Home Products, Inc.

Printed in the U.S.A.

High standards of quality at Electrolux Home Products, Inc. mean 

we are constantly working to improve our products. We reserve the right 

to change specifications or discontinue models without notice.

25

3

/

4

"

Power supply

location

(left bottom

rear)
Gas

connection

location

(right bottom

rear)

28

5

/

16

"

27

1

/

2

"

Overall

depth

including

oven door

in 90

°

open

position –

45

1

/

4

"

Side

30"

31

1

/

2

"

35

5

/

8

"

Adjustable

to

36

5

/

8

"

13

/

16

"

Front

5"min. to nearest

combustible

wall (either side

of unit)

Location for main shutoff valve

recommended in right cabinet

with gas supply pipe routed

through cabinet side wall

Front Face of Cabinet

22

7

/

8

"min.

23

1

/

4

"max.

1

1

/

8

"

21

3

/

4

"min.

22

1

/

8

"max.

**

Countertop

13"

max.

30"min.

18"

min.

24"min.

1

/

2

"min.

WALL

 31

1

/

2

"

(critical)

30 

±

1

/

16

"*

Approx.

1

7

/

8

"

Hatched area

should be flat

and leveled

1

1

/

2

"

max.

Shave raised
edge to clear
space for
31

1

/

2

" wide

cooktop rim

30 

±

1

/

16

"*

21

3

/

4

"min.

22

1

/

8

"max.

**

1

/

2

"min.

Locate grounded junction box

or wall outlet 8"-17" from right

cabinet and 2"- 4" from floor

35

3

/

4

"

min.

36

5

/

8

"

max.

Locate cabinet

doors 1" min.

from cutout

opening

3

/

8

"min.

24" min. clearance

with protected cabinet bottom

30" min. for unprotected

 

*Cabinet and countertop

cutout width should match

 

**24" with optional

backguard installed

30" Gas Built-In Range Specifications

Product Weight – 250 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.2 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120V =  10 Amps

Always consult local and national electric and gas codes.

Range ships with 3/4" factory regulator. 

LP Gas conversion kit supplied.

Gas supply piping can be routed through side wall of right cabinet. 
Right side cabinet is ideal location for main shutoff valve.

Countertop MUST be level in all directions and adjustable range 
height at least 1/16" greater than tallest cabinet height, to ensure metal
rangetop flange will fit properly on countertop edge.

When installing optional Backguard Kit, cutout depth of 21-3/4" 
minimum / 22-1/8" maximum needs increased to 24".

Overhead cabinetry should not exceed a 13" maximum depth.

Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.

Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than 1/4"
flame-retardant millboard covered with not less than No. 28 MGS sheet
steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. Allow
30" minimum clearance when cabinet is unprotected.

Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.

To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.

When installing range into existing cutout depth greater than 22-1/8",
optional 2" Rear Filler Kit available.

Countertop Preparation 

For detailed preparation instructions, refer to installation guide on the web.

Flat square-finish (flat) countertop requires no preparation since rangetop
flange lays directly on countertop edge. 

Formed front-edged countertops require front molded edge to be shaved
flat 3/4" from each front corner of opening. 

Tile countertops may need cut back 3/4" from each front corner of
opening and / or rounded edge flattened. 

For existing cutout width greater than 30-1/16" reduce the 3/4" overlap
dimension or for cutout width of 29", replace actual side trim panels with
smaller side trim panels, available with optional Side Trim Kit 

(refer to

detailed kit installation instructions).

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

Wok Ring – (PN # 318254307).

Simmer Plate – (PN # 318254206).

2" Rear Filler Kit: S – (PN # 903113-901S).

Side Panel Kit: S – (PN # 903102-901S).

Backguard Kit: S – (PN # 903111-901S).

Side Trim Kit: S – (PN # 903110-901S).