20
electrolux
Electrical Connections
Any electrical work required to install this hob should be
carried out by a qualified electrician or competent person, in
accordance with the current regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should these safety
measures not be observed.
This hob is designed to be connected to a 230 V 50 Hz AC electrical
supply.
Before switching on, make sure the electricity supply voltage is the same
as that indicated on the hob rating plate. The rating plate is located on the
bottom of the hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cable.
The wires in the mains lead are coloured in accordance with the following
code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
1.
Connect the green and yellow (earth) wire to the terminal which is
marked with the letter 'E' or the earth symbol
or coloured green
and yellow. The earth wire should be about 2 cm longer than the neutral
and live wires.
2.
Connect the blue (neutral) wire to the terminal which is marked with
the letter 'N' or coloured black.
3.
Connect the brown (live) wire to the terminal which is marked with the
letter 'L' or coloured red.
Upon completion there must be no cut, or stray strands of wire present
and the cable clamp must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket is a serious safety
(shock) hazard. Ensure that the cut off plug is disposed of
safely.
The replacement of electric cable must be carried out exclu-
sively by the service force centre or by personnel with similar
competencies, in accordance with the current regulations.