Heat input
Rapid burner:
3.0 kW
Semi-rapid burn-
er:
2.0 kW
Auxiliary burner:
1.0 kW
Electric zone:
1.5 kW
TOTAL GAS
POWER:
G20 (2H) 20 mbar
= 6.0 kW
G30/G31 (3B/P)
30/30 mbar = 418
g/h
TOTAL ELECTRIC
POWER:
1.5 kW
Electric supply:
230 V ~ 50 Hz
Gas category:
II2H3B/P
Gas connection:
G 1/2”
Gas supply:
G20 (2H) 20 mbar
Appliance class:
3
By-pass diameters
Burner
Ø By-pass in
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
42
Gas burners
BURNER
NORMAL
POWER
RE-
DUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG (Butane/Pro-
pane)
G30/G31 (3B/P)
30/30 mbar
kW
kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
g/h
Auxiliary
1.0
0.33
70
0.095
50
73
Semi-rap-
id
2.0
0.45
96
0.190
71
145
Rapid
3.0 (nat.
gas)
2.8 (LPG)
0.75
119
0.286
86
204
Gas burners G20 13 mbar - only Russia
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 13 mbar
kW
kW
inj. 100/mm
m³/h
Auxiliary
0.9
0.33
80
0.095
Semi-rapid
1.4
0.45
105
0.148
Rapid
1.9
0.75
120
0.201
ENVIRONMENT CONCERNS
Recycle the materials with the symbol
.
Put the packaging in applicable containers
to recycle it.
Help protect the environment and human
health and to recycle waste of electrical
and electronic appliances. Do not dispose
appliances marked with the symbol with
46 www.electrolux.com
Summary of Contents for EHM 6315
Page 20: ... Odřízněte a vyhoďte síťový kabel Vnější plynové potrubí slisujte 20 www electrolux com ...
Page 93: ...TÜRKÇE 93 ...
Page 94: ...94 www electrolux com ...