62
The appliance is arranged to operate on a 230 V single-
phase power supply. Connection must be made in
compliance with current standards and regulations.
Before carrying out the connection, make sure:
1) the limiter valve and the electrical system can
take the appliance load (refer to the serial no.
plate);
2) the supply system is equipped with an efficient
earth connection in compliance with current
standards;
3) the socket or omnipolar switch used are easily
accessible with the appliance installed.
Fit the cable with a plug suitable for the load and connect
it to a suitable safety socket.
To connect directly to the mains, a suitable omnipolar
switch with contact gap of at least 3 mm complying with
current standards must be installed between the
appliance and the network.
The yellow/green earth wire must not be interrupted by
the switch.
The brown phase wire (coming from terminal “L” on the
terminal block) must always be connected to the power
supply phase wire.
In any case the power cable must be positioned in such
a way that no part of it reaches a temperature of more
than 90°C.
An example of an optimum path is given in Fig. 4. The
cable is guided by means of clamps fixed to the side of
the cabinet, in order to avoid any contact with the
equipment beneath the cooktop.
REPLACING THE POWER CABLE
When replacing the power cable only use H05V
2
V
2
-F
T90 type cables suitable for the load and operating tem-
perature. Also, the yellow/green earth wire must be
approx. 2 cm longer than the phase and neutral wires
(Fig. 5).
After connection, test the heating elements by operating
them for about 3 minutes.
Electrical connection