background image

3

Contents

For the User

For the Installer

Important Safety Information

2

Description of the Hob

3

Operation

4

Maintenance and Cleaning

4

Something Not Working?

5

Service and Spare Parts

5

Customer Care Department

6

Guarantee Conditions

6

Engineers technical data

9

Installation

10

Important Safety Requirements

10

Building In

11

Electrical connections

12

Wiring Diagram

13

Fault Finding

13

Commissioning

15

Conversion from Natural Gas to LPG

15

Description of the Hob

1.

Hob Top

2.

Rapid Burner

3.

Semi-rapid Burners

4.

Auxiliary Burner

5.

Control knobs

6.

Electric Ignition Push Button

1

3

2

4

3

5

6

Summary of Contents for EHG 680

Page 1: ...Gas hobs Mod EHG 673 EHG 680 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance 35675 8201 GB ...

Page 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Page 3: ...Care Department 6 Guarantee Conditions 6 Engineers technical data 9 Installation 10 Important Safety Requirements 10 Building In 11 Electrical connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 Description of the Hob 1 Hob Top 2 Rapid Burner 3 Semi rapid Burners 4 Auxiliary Burner 5 Control knobs 6 Electric Ignition Push Button 1 3 2 4 3 5 6 ...

Page 4: ...your local Electrolux Service Centre Before any maintenance or cleaning can be carried out you must DISCONNECT the hob from the electricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool The Hob Top Regularly wipe over the hob top using a soft cloth well wrungoutinwarmwatertowhichalittlewashingupliquid has been added Avoid t...

Page 5: ...oes not operate correctly contact your local Service Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown In the event of your appliance requiring service or if you wish to...

Page 6: ...environment plus those which are the subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications The guarantee starts from the date you first purchased your product The guarantee is for the same p...

Page 7: ... Inveralmond OWN SALES Perth PH1 3AF SHETLAND 3 4 Carlton Place Lerwick Shetland OWN SALES ZE1 0PW SHETLAND Bolts Shetland 26 North Road Lerwick OWN SALES Shetland ZE1 0PE WHALSAY Leask Electrical Harisdale Symbister Whalsay OWN SALES Shetland ZE2 9AA NORTHERNIRELAND BELFAST Owenmore House Kilwee Business Park Dunmurry Belfast BT17 0HD WALES CARDIFF Unit 4 Guardian Industrial Estate Clydesmuir Roa...

Page 8: ...West Mill Gravesend Kent DA11 0DL IPSWICH Unit 6C Elton Park Business Centre Hadleigh Road Ipswich IP2 0DD LETCHWORTH 16 17 Woodside Ind Park Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road Maidenhead Berkshire SL6 8BY MOLESEY 10 Island Farm Avenue West Molesey Surrey KT8 2UZ NEWBURY 9 Pipers Court Berkshire Drive Thatcham Be...

Page 9: ...able plug fitted with a 3 amp cartridge fuse Instructions for the Installer Engineers technical data BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINALTHERMAL 3 0 0 65 2 0 0 45 1 0 0 33 POWER kW NOMINALFLOW 0 286 0 062 0 190 0 043 0 095 0 031 RATE m3 h NOZZLEREFERENCE 119 Adjust 96 Adjust 70 Adjust 1 100 mm NOMINALTHERMAL 2 8 0 65 2 0 0 45 1 0 0 33 POWER ...

Page 10: ... room but not in a bathroom shower room or garage Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edge...

Page 11: ...allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Connectio...

Page 12: ...wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown...

Page 13: ...ss than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal eviden...

Page 14: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 15: ...d ignite another burner The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies F F Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method Ensur...

Page 16: ...up The world s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...

Reviews: