7
The following instructions about installation and
maintenance must be carried out by qualified
personnel in compliance with the regulation in
force.
The side walls of the unit in which the hob is
going to be installed, must not exceed the height
of the working top.
Avoid installing the appliance in the proximity of
inflammable materials (e.g. curtains, tea towels
etc.).
The appliance must be electrically disconnected
before all interventions. If any electric supply to
the appliance is required to carry out the work,
ensure all the necessary precautions are followed.
THE MANUFACTURER WILL NOT ACCEPT
LIABILITY, SHOULD ANY OF THE OTHER SAFETY
INSTRUCTIONS INCORPORATED IN THIS BOOK
OR THE REGULATION IN FORCE BE IGNORED.
Instruction for the Installer
Gas Burners Rating
Rapid Burner
3,0 kW (G20) - 2,8 kW (G30/G31)
Semirapid Burner
2,0 kW
Auxiliary Burner
1,0 kW
Appliance Class
3
Category
II2H3B/P
Setting
Natural Gas G20 - 20 mbar
Gas connection
G 1/2"
Technical Data
Electric Supply
230 V 50 Hz
Hob recess dimensions
Length
550 mm
Width
470 mm