Fig. 4

Choose fixed connections or use a flexible pipe in
stainless steel in compliance with the regulation in force.
If using flexible metallic pipes, be careful they do not
come in contact with mobile parts or they are not
squeezed. Use the same attention when the hob is
combinated with an oven.
IMPORTANT  -  To ensure a correct operation, a saving
of energy and the long-life of the appliance, the voltage
pressure of the appliance must correspond to the
recommended values.

The adjustable connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2". Interpose the
sealing between the components as shown in Fig. 4.
Screw the parts without forcing, adjust the connection in
the required direction and tighten everything.

Connection using flexible non
metal pipes

When the connection can be easily inspected in its full
extent, there is the chance to use a flexible pipe
according to the rules in force. The flexible pipe must be
tightly fixed using clamps according to the rules in force.

LPG : use the rubber pipe holder «D» (Fig. 4).
Always insert the gasket «B». Then proceed with the
gas connection.
The flexible pipe should be made ready for use in such
a way that:
-

nowhere it can reach overtemperature, other than
room temperature, higher than 30°C; if the flexible
pipe, to reach the cock, must run behind the range,
it must be installed as shown in Fig. 4;

-

it is no longer than 1500 mm;

-

it shows no throttles;

-

it is not subject to traction or torsion;

-

it doesn't get in touch with cutting edges or corners;

-

it can be easily inspected in order to check its
condition.

The control of preservation of the flexible pipe consists
in checking that:
-

it doesn't show cracks, cuts, marks of burnings both
on the end parts and on its full extent;

-

the material is not hardened, but shows its normal
elasticity;

-

the fastening clamps are not rusted;

-

expiry term is not due.

If one or more abnormalities are seen, do not repair the
pipe, but replace it.

Important

Once installation is complete, check the perfect
seal of every pipe fitting, using a soapy solution,
never a flame

Gas connection

A) Ramp with ending nut

B) Seal

C) Adjustable connection

D) Rubber pipe holder for LPG

D

Summary of Contents for EHG 671

Page 1: ...Gas hobs Kombinirana plinska i plinsko strujna plo ča Vgradna kuhalna plošča Mod EHG 671 EHM 6731 EHM 6722 INSTRUCTION BOOKLET UPUTE ZA UPOTREBU NAVODILA ZA UPORABO 35679 4801 HR RO SI SK BG ...

Page 2: ...s Thisappliance hasbeendesignedfornonprofessional purpose in private houses only It is meant to cook ediblefoodstuffonlyandMUST NOTbeusedforanyother purposes It is dangerous to alter the specification in any way Forhygieneandsafetyreasons thisapplianceshould be kept clean at all times A build up of fats or other foodstuff could result in a fire English These warnings are provided in the interest o...

Page 3: ...s regular and adjust it as required If you cannot light the flame even after several attempts check the cap Fig 1 lett A and the crown Fig 1 lett B are in the correct position Toputtheflameout turntheknobtothesymbol Always turn the flame down or put it out before taking the pans off the burner Contents This appliance complies with the following E E C Directives 73 23 90 683 Low Voltage Directive 8...

Page 4: ...the electric plate It is important to note that the plate may smoke and produce a slightly unpleasant odour when used for the first time This is quite normal and will disappear after a short while Using the plates correctly When cooking by electric saucepans should have a thick base and be perfectly flat in order to ensure total contact with the plate and consequently perfect conduction Fig 2 b Oc...

Page 5: ...d Cleaning of the hotplates Spills on the hotplates should be removed using warm water and a soft cloth Alternatively wipe the plates with a drop of olive oil on a kitchen towel while the plates are still warm Periodic Maintenance Periodically ask your local Service Centre to check the conditions of the gas supply pipe and the pressure adjuster if fitted To ensure the good operation of the hob and...

Page 6: ...pliance in the proximity of inflammable materials e g curtains tea towels etc The appliance must be electrically disconnected before all interventions If any electric supply to the appliance is required to carry out the work ensureallthenecessaryprecautionsarefollowed THE MANUFACTURER WILL NOT ACCEPT LIABILITY SHOULDANY OF THE OTHER SAFETY INSTRUCTIONS INCORPORATED IN THIS BOOK OR THE REGULATION I...

Page 7: ...ccording to the rules in force LPG use the rubber pipe holder D Fig 4 Always insert the gasket B Then proceed with the gas connection The flexible pipe should be made ready for use in such a way that nowhere it can reach overtemperature other than room temperature higher than 30 C if the flexible pipe to reach the cock must run behind the range it must be installed as shown in Fig 4 it is no longe...

Page 8: ...recommendationgiveninFig 5 The plug has to be fitted in a proper socket Ifconnectingtheappliancedirectlytotheelectricsystem it is necessary that you install a double pole switch between the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts and ofatypesuitablefortherequiredloadincompliancewith the current rules Theconnectioncablehastobeplacedinorderthat ine...

Page 9: ...river adjust the by pass screw see Fig 8 If changing from natural gas to LPG completely tighten clockwise the screw until a small regular flame is obtained If changing from LPG to natural gas unscrew about 1 4 turn the by pass screw until a small regular flame is obtained Finally check the flame does not go out when quicklyturningtheknobfromthemaximumposition to the minimum position Thisprocedurec...

Page 10: ...om the rear wall of 55 mm If there are side walls or sides of the furniture unit near the hob the cut out edges must have a minimum distance of 100 mm Hanging furniture units or hoods must be placed at 650 mm minimum from the hob R Rapid burner SR Semirapid burner A Auxiliary burner P Electric hotplate Building In SR SR A R 580 500 P SR A R 580 500 P P SR A 580 500 Mod EHM 6731 Mod EHM 6722 Mod EH...

Page 11: ...ear edge taking care that the sealings meet without overlapping 3 Fix the hob with the relevant screws Fig 10 The traction of the screws is able to trace the sealing any excess of which can be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids Fig 9 Fig 10 a Sealing gasket Dimensions are given in millimeters FO 2098 FO ...

Page 12: ...e intervention is needed Fig 14 Kitchen unit with oven The hob recess dimensions must comply the indication given in Figs 13 and 14 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 15 e 16 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to all...

Reviews: