Wiring diagram
Permanent Connection
In the case of a permanent connection, it is necessary that you install a
double pole switch between the hob and the electricity supply (mains),
with a minimum gap of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the current electric
regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cord does not come into contact
with surfaces with temperatures higher than 90 deg. C.
Supply cable replacement
The cable used to connect the hob to the electrical supply must comply to
the specifications given below.
A. IGNITOR SWITCH
B. IGNITOR UNIT
Min. size
Cable/flex
Cable / flex type
Fuse
0.75 mm
2
H05 V2V2-F (T90)
3 A