9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20/G25 (2E+) 20/25 mbar 7,6 kW
Gas re‐
placement:
G30 (3+) 28-30 mbar
545 g/h
G31 (3+) 37 mbar
536 g/h
Electric supply: 220-240 V ~ 50-60 Hz
Appliance cat‐
egory:
II2E+3+
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20/G25 20/25 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid
2,9
0,75
119
Semi-rapid
1,85
0,45
92
Auxiliary
1,0
0,33
70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid
2,7
0,75
86
196
193
Semi-rapid 1,9
0,45
71
138
136
Auxiliary
1,0
0,33
50
73
71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification
EGT6242NVK
Type of hob
Built-in hob
Number of gas burners
4